Setting the Buzzers
You can turn on/off the following buzzers.
•TAPE END buzzer: Beeps when the tape reaches its end or the tape counter shows the reading set on the “TAPE END” option in the SET UP menu.
•Warning buzzer:Beeps when the unit outputs a warning signal from the WARNING OUT terminal.
6
r P
p 0 ( )
MENU | SHIFT b | DATA +/– |
SHIFT v |
|
|
1 Press MENU.
The main menu appears.
1. CLOCK SET
DAYLIGHT SET
LANGUAGE
2.TIMER SET
3.SET UP USED TIME
2 Press SHIFT vto select 3.SET UP/USED TIME, then press SHIFT b.
The SET UP menu appears on the screen.
[ SET UP ]
TAPE | |
END ALARM | END |
TAPE END | REW |
APC | ON |
CLOCK ADJ | 0 1 : 0 0 |
BUZZER | ON |
THREAD CHECK | ON |
[ USED TIME ] | |
HEAD | 00005H |
3 Press SHIFT vto flash the setting of “BUZZER.”
[ SET UP ]
TAPE | |
END ALARM | END |
TAPE END | REW |
APC | ON |
CLOCK ADJ | 0 1 : 0 0 |
BUZZER | ON |
THREAD CHECK | ON |
[ USED TIME ] | |
HEAD | 00005H |
4 Set to ON or OFF using DATA
[ SET UP ]
TAPE | |
END ALARM | END |
TAPE END | REW |
APC | ON |
CLOCK ADJ | 0 1 : 0 0 |
BUZZER | OFF |
THREAD CHECK | ON |
[ USED TIME ] | |
HEAD | 00005H |
5 Press MENU twice to return to the normal display.
To stop the TAPE END buzzer
Press the pSTOP button.
To stop the warning buzzer
Press one of the tape operation buttons (e.g. pSTOP).
12 (US)