Symptom | Cause and Remedy |
|
|
Color balance is incorrect. | • Picture has not been adjusted properly. |
| c Adjust the picture (see page 26). |
| • Projector is set to wrong color system. |
| c Set COLOR SYS in the PICTURE CTRL menu to match the |
| color system being input (see page 27). |
|
|
The picture is too dark. | • Contrast or brightness has not been adjusted properly. |
| c Adjust the contrast or brightness in the PICTURE CTRL menu |
| properly (see page 26). |
|
|
The picture is not clear. | • Picture is out of focus. |
| c Adjust the focus (see page 22). |
| • Condensation has occurred on the lens. |
| c Leave the projector for about two hours with the power on. |
|
|
The picture appears too | • SHIFT in the INPUT SETTING menu has not been adjusted |
small on the screen. | properly. |
| c Adjust SHIFT in the INPUT SETTING menu properly (see |
| page 28). |
|
|
The picture flickers. | • DOT PHASE in the INPUT SETTING menu has not been adjusted |
| properly. |
| c Adjust DOT PHASE in the INPUT SETTING menu properly |
| (see page 27). |
|
|
Symptom | Cause and Remedy |
|
|
No sound. | • Cable is disconnected or the connections are wrong. |
| c Check that the proper connections have been made (see page |
| 15). |
|
|
When sound is input | • Monaural sound is being input through the AUDIO connector. |
through AUDIO connector, | c Input stereo sound. |
sound comes through one |
|
channel only. |
|
|
|
Symptom | Cause and Remedy |
|
|
The Remote Commander | • The Remote Commander batteries are dead. |
does not work. | c Replace with a new battery (see page 12). |
|
|
Symptom | Cause and Remedy |
|
|
The LAMP/COVER | • The lamp cover or the air filter cover is detached. |
indicator flashes. | c Attach the cover securely (see page 31). |
|
|
The LAMP/COVER | • The lamp has reached the end of its life. |
indicator lights up. | c Replace the lamp (see page 31). |
| • The lamp becomes a high temperature. |
| c Wait for 90 seconds to cool down the lamp and turn on the |
| power again (see page 23). |
|
|
GB 34 Troubleshooting