Symptom | Cause and Remedy |
|
|
The TEMP/FAN indicator | • The fan is broken. |
flashes. | c Consult with qualified Sony personnel. |
|
|
The TEMP/FAN indicator | • The internal temperature is unusually high. |
lights up. | c Check to see if nothing is blocking the ventilation holes. |
|
|
Both the LAMP/COVER | • The electrical system breaks down. |
and TEMP/FAN indicators | c Consult with qualified Sony personnel. |
light up. |
|
|
|
Warning Messages
Use the list below to check the meaning of the messages displayed on the screen.
Message | Meaning and Remedy |
|
|
|
|
|
|
High temp.! | • Internal temperature is too high. |
|
|
Lamp off in 1 min. | c Turn off the power. |
|
|
| c Check to see if nothing is blocking the ventilation holes. |
|
|
|
|
|
|
Frequency is out of range! | • This input signal cannot be projected as the frequency is out of the |
|
|
|
| ||
| acceptable range of the projector. |
|
|
|
|
| |
|
|
| |
| c Input a signal that is within the range of the frequency. |
|
|
|
|
| |
|
|
| |
|
|
| |
| • The resolution setting of the output signal of a computer is too |
|
|
|
|
| |
|
|
| |
| high. | Maintenance | |
| c Set | ||
| c Set the setting of output to XGA (see page 15). |
|
|
Please check | • You have input RGB signal from the computer when |
|
|
setting. | the SET SETTING menu is set to COMPONENT. |
|
|
|
|
|
|
Please replace the LAMP. | • It is time to replace the lamp. |
|
|
| c Replace the lamp. |
|
|
|
|
|
|
Caution Messages
Use the list below to check the meaning of the messages displayed on the screen.
Message | Meaning and Remedy |
|
|
NO INPUT | • No input signal |
| c Check connections (see page 15). |
|
|
Not applicable! | • You have pressed the wrong key. |
| c Press the appropriate key. |
|
|
Troubleshooting 35 GB