Symptom | Cause and Remedy |
|
|
The picture is not clear. | • Picture is out of focus. |
| c Adjust the focus. |
| • Condensation has occurred on the lens. |
| c Leave the projector for about two hours with the power on. |
|
|
The image extends beyond | • The APA key is pressed although there are black edges around the |
the screen. | image. |
| c Display the full image on the screen and press the APA key. |
| c Adjust Shift in the INPUT SETTING menu properly. |
|
|
The picture flickers. | • Dot Phase in the INPUT SETTING menu has not been adjusted |
| properly. |
| c Adjust Dot Phase in the INPUT SETTING menu properly. |
|
|
Indicators
POWER SAVING | Lights up when the projector is in power saving mode |
|
|
TEMP/FAN | Lights up when temperature inside the projector becomes unusually |
| high. Check to see if anything is blocking the ventilation holes. |
|
|
| Flashes when the fan is broken. Consult with qualified Sony |
| personnel. |
|
|
LAMP/COVER | Lights up when the lamp has reached the end of its life or becomes a |
| high temperature. Wait for 120 seconds to cool down the lamp and |
| turn on the power again, or replace the lamp. |
| Or the electrical system may break down. Consult with qualified |
| Sony personnel. |
|
|
| Flashes when the lamp cover is not secured firmly. Attach the cover |
| securely. |
|
|
I /1 indicator | Lights in red when the projector is in standby mode. Once in standby |
| mode, you can turn on the projector with the I /1 key. |
|
|
| Lights in green when the power is turned on. |
|
|
| Flashes in green for about several seconds from the projector is |
| turned on until the projector is ready to operate. Also, flashes in |
| green for about 120 seconds while the cooling fan runs after the |
| power is turned off with the I /1 key. During this time, you will not |
| be able to operate on the projector. |
|
|
GB 14 Troubleshooting