Symptom | Cause and Remedy |
|
|
|
|
c Set “Status” in the Setup | menu to “On.” (1 page 43) | |
appear. |
|
|
|
|
|
Symptom | Cause and Remedy |
|
|
The remote control does | c Batteries could be weak. Replace with new batteries. (1 page |
not work. | 7) |
| c Insert the batteries with correct polarities. (1 page 7) |
|
|
Others
The LAMP/COVER or TEMP/FAN indicator on the control panel lights up or flashes if there is any trouble with your projector.
LAMP/COVER indicator
TEMP/FAN indicator
LAMP/ | TEMP/ | POWER | ON/ |
COVER | FAN | SAVING | STANDBY |
Symptom | Cause and Remedy |
|
|
LAMP/COVER flashes. | c Attach the lamp cover or the air filter cover securely. (1 |
| pages 49 and 50) |
|
|
LAMP/COVER lights up. | c The lamp has reached the end of its life. Replace the lamp. (1 |
| page 49) |
| c The lamp becomes a high temperature. Wait until the lamp |
| cools, and then turn on the power again. (1 page 25) |
|
|
TEMP/FAN flashes. | c The fan is broken. Consult with qualified Sony personnel. |
|
|
TEMP/FAN lights up. | c The internal temperature is unusually high. Check to see if |
| nothing is blocking the ventilation holes or whether or not the |
| projector is being used at high altitudes. |
|
|
LAMP/COVER and | c Disconnect the AC power cord, connect it, then turn on the |
TEMP/FAN light up. | power again. If the indicators still light up, the electrical system |
| breaks down. Consult with qualified Sony personnel. |
|
|
Troubleshooting 47