Notes for Installation

Unsuitable Installation

Do not install the projector in the following situations. These installations may cause malfunction or damage to the projector.

Poorly ventilated

Allow adequate air circulation to prevent internal heat build-up. Do not place the unit on surfaces (rugs, blankets, etc.) or near materials (curtains, draperies) that may block the ventilation holes. When internal heat builds up due to blockage of the ventilation holes, the temperature sensor may function, a warning message will be displayed, and the power may be turned off automatically after one minute.

Leave space of more than 50 cm (19 3/4 inches) around the unit.

Be careful that the ventilation holes do not inhale tiny objects such as pieces of paper.

Highly heated and humid

Avoid installing the unit in a location where the temperature or humidity is very high, or the temperature is very low.

To avoid moisture condensation, do not install the unit in a location where the temperature may rise rapidly.

Notes for Installation

Very dusty

Avoid installing the unit in a location where there is a lot of dust; otherwise, the air filter will clog. The dust blocking the air through the filter may cause the internal heat level of the projector to rise. Clean the filter periodically.

Unsuitable Conditions for Use

Do not do any of the following.

Toppling the unit

Avoid standing the unit on its side as the unit may topple over. This may cause a malfunction.

Tilting the unit more than 15 degrees

Avoid tilting the unit at an angle of more than 15 degrees. Installation of the unit in this manner may cause a malfunction.