22 GoldMike MK2
Sync Input
The SYNC input allows you to feed an external signal into 
the converter to control the sample r ate (since this is an AD 
converter, the SYNC Input is no audio signal i nput). Connect an 
S/P-DIF output from your master source (e.g. s ound card) to the 
SYNC input. The AD converter w ill automatically switch to the 
same sample rate that is received. The 2376 is not equipped to 
accept Word Clock synchronization.
The yellow Sync Lock LED illuminates wh en a valid sync signal 
is present at the Sync input and the conver ter is automatically 
synchronized to the external sample rate.
To prevent interference, the internal oscil lators are automati-
cally disabled when an external clock signal is present. If the 
sync signal is no longer present (e.g. in the c ase of a dropout), 
the converter automatically rever ts to the sample rate sele cted 
via the converter’s control switc hes.
Lundahl-Transformers
Transformers have characteristics usually associated with other 
analog components like tubes or coils—they sound “warmer”, 
and punchier especially in the bass an d mid area and deliver 
improved presence without boost ing the top end. One reason 
for this is that transformers c ancel out a large amount of odd 
harmonics (those portions of an audi o signal that sound harsh 
to human ears).
Equipping the GoldMike MK2 with transformer-based inputs 
and outputs means you benefit f rom their unique characteris-
tics.
IMPORTANT: The GoldMike MK2’s input transfor mer delivers up 
to +14 dB of additional passive gain, which must be added to 
the printed values.
Options