4. DOOR LOCKS

Negative Lock Output / Positive Unlock Output (GREEN)

Negative Unlock Output / Positive Lock Output (BLUE)

Negative Second Door Unlock Output (BLUE/GREEN)

Adding Aftermarket Actuators:

After installing aftermarket actuators, Code Alarm part DA-1 (not supplied). Connect the GREEN and BLUE wires shown in diagram 16 below. Use (1) Code Alarm part DLRK (Door Lock Relay Kit, not included) or

(2) Code Alarm part HDRLY (SPDT relay, not included).

Diagram 16

 

 

 

 

 

 

Fused +12 Volt

 

87

 

Battery Source

 

 

 

Door Lock

87a

 

GREEN (-) Lock Output

Actuator

85

86

 

 

 

 

30

 

Chassis

 

 

 

M

 

 

Ground

 

 

 

 

 

 

Fused +12 Volt

 

87

 

Battery Source

 

 

 

 

87a

 

BLUE (-) Unlock Output

 

86

85

 

 

 

30

 

 

 

 

 

Chassis

 

 

 

Ground