Clark Pump/Membrane Module
Pressure Relief Valve
The membrane maximum temperature specification is 120F. This module must be installed in an area that maintains a temperature below 120F (50C). A cool location is preferable. It may be placed as high in the boat as you desire. Make sure that the area around and under the pump does not have any water sensitive equipment. Water will be spilled during any repairs or if a leak occurs.
Be sure you will have access to the pressure relief valve on the Clark pump.
The Clark pump/membrane module comes complete with a mounting system. Be sure to use the supplied washers on the rubber feet. Use it as a template for drilling the mount holes. You may mount the Clark Pump in any position, even upside down.
Membrane Pressure Vessel Mounting
The Clark pump and membrane assembly has been