WIRE SIZE CHART
Newport MkII 12V DC System Wiring
Wire Length FT. | Meters | AWG. | SQ MM |
10 | 3 | 10 | 6 |
15 | 4.5 | 8 | 10 |
20 | 6.1 | 6 | 16 |
25 | 7.6 | 4 | 25 |
30 | 9.4 | 4 | 25 |
35 | 10.6 | 4 | 25 |
40 | 12 | 2 | 35 |
45 | 14 | 2 | 35 |
50 | 15 | 2 | 35 |
MkII 24V | Meters | AWG. | SQ MM |
10 | 3 | 12 | 4 |
15 | 4.5 | 10 | 6 |
20 | 6.1 | 8 | 10 |
25 | 7.6 | 8 | 10 |
30 | 9.4 | 8 | 10 |
35 | 10.6 | 6 | 16 |
40 | 12 | 6 | 16 |
45 | 14 | 6 | 16 |
50 | 15 | 4 | 25 |
Wire length for a pair of wires is measured from source circuit breaker or fuse to control terminal block.