43
B
D
43With lettering on outside of belt and positioned as shown in
box on (D), slide new belt over motor pulley (B).
44
C
E
D
44Insert agitator through belt and place belt in belt guide (C) on
agitator.
Should the agitator shield (D) become dislodged while replacing the belt or the agitator, reposition it as shown noting the placement of its belt guide (E).
45 |
G |
F |
45Grasp agitator firmly and fit it into position by first sliding
end opposite the belt into the rec- tangular slot (F) on side of cleaner.
Pull other side of agitator (G) into place.
Turn agitator making sure belt is not pinched between agitator and agi- tator shield.
46 |
46Reposition bottom plate and 4 Phillips head screws. Tighten
screws securely.
The edge groomers
When to replace
The edge groomers located on both sides of the nozzle should be replaced when they appear worn.
What to buy
When purchasing a pair of edge groomers, ask for part no.
How to replace
Disconnect cleaner from electrical outlet.
Remove bottom plate as described in “The belt” section (Fig. 41).
47 |
47Lift off both old edge groomers and slide new edge groomers
into position as shown.
Reposition bottom plate and secure with 4 Phillips head screws.
The agitator brush roll
When to replace
48To check condition of brushes, move edge of a card across bot-
tom plate while turning agitator. To maintain cleaning effectiveness, replace agitator if brushes do not touch card.
10
48 |
What to buy
When purchasing a new agitator, ask for
part no.
How to replace
Disconnect cleaner from electrical outlet.
Remove bottom plate, belt and agi- tator following directions in “The belt” section beginning with Fig. 41.
Discard old agitator.
Continue following the directions in “The belt” section to reposition belt, new agitator and bottom plate.