FOG HORN TIMING CHART

TYPE

PATTERN

 

 

 

 

 

 

 

 

USAGE

UNDERWAY

One 5-second blasts every 120 seconds.

Motor vessel underway and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

making way.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Listen Back

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

120s

 

 

 

 

 

 

 

 

 

 

 

STOP

Two 5-second blasts (separated by 2

Motor vessel underway but

 

seconds) every 120 seconds.

 

 

 

 

 

 

 

 

stopped (not making way).

 

 

 

 

 

5s

 

5s

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Listen Back

 

 

 

 

 

 

 

 

 

 

 

 

 

2s

2s

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

120s

 

 

 

 

 

 

 

 

 

 

SAIL

One 5-second blasts followed by two 1-

Sailing vessel underway, fish-

 

second blasts (separated by 2 seconds)

ing vessel (underway or an-

 

every 120 seconds.

 

 

 

 

 

 

 

 

chored), vessel not under

 

 

 

 

1s 1s

1s 1s

command, a vessel restricted

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

in her ability to maneuver (un-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Listen Back

 

 

 

 

 

 

 

 

 

derway or at anchor), or a ves-

 

 

 

2s 2s

2s 2s

sel towing or pushing another

 

 

 

 

 

 

 

 

 

 

 

 

 

 

120s

 

 

 

 

 

 

 

 

 

 

ahead.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TOW

One 5-second blasts followed by three 1-

Vessel under tow (manned).

 

second blasts (separated by 2 seconds)

 

 

every 120 seconds.

 

 

 

 

 

 

 

 

 

 

 

 

 

1s 1s 1s

1s 1s 1s

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Listen Back

 

 

 

 

 

 

 

 

 

 

 

 

 

2s 2s 2s

2s 2s 2s

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

120s

 

 

 

 

 

 

 

 

 

 

 

AGROUND

One 11-second rings every 60 seconds.

Vessel is aground.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Listen Back

 

 

60s

 

ANCHOR

One 5-second rings every 60 seconds.

Vessel is at anchor.

Listen Back

60s

GX5500S

 