Standard Horizon MDS-1, MDS-8 Radar Antenna Connections, Dome Connections, Open Array Connections

Models: MDS-9 MDS-8 MDS-10-5 MDS-10-4 MDS-1

1 38
Download 38 pages 11.43 Kb
Page 13
Image 13

Standard Horizon Chart Plotter. Do not omit the in-line fuse unless a dedicated and fused terminal is available. If so, install a 5 Amp fuse.

Terminal Strip C - Radar Cable

This terminal strip is used to connect the Radar Antenna.

2.6RADAR ANTENNA CONNECTIONS

2.6.0DOME Connections

 

 

 

 

 

RADAR CABLE

 

 

 

 

WIRE COLOR

FUNCTION

 

 

 

 

BLACK

DATA GROUND

 

 

 

 

 

 

 

 

ORANGE

DATA OUT+

 

 

 

 

 

 

 

 

YELLOW

DATA OUT-

 

 

 

 

 

 

 

 

BROWN

DATA IN+

 

 

 

 

 

 

 

 

RED

DATA IN-

 

 

 

 

 

 

 

 

GREEN

POWER ON/OFF SWITCH

 

 

 

 

BLUE

POWER ON/OFF SWITCH

 

 

 

 

BLACK

RADAR BATTERY GROUND

 

 

 

 

 

 

 

 

WHITE

RADAR BATTERY POSITIVE

 

 

 

 

 

 

 

Figure 2.6.0 - DOME Connections

2.6.1 OPEN ARRAY Connections

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RADAR CABLE

 

 

 

 

 

WIRE COLOR

FUNCTION

 

 

 

 

BLACK

DATA GROUND

 

 

 

 

 

 

 

 

ORANGE

DATA OUT+

 

 

 

 

 

 

 

 

YELLOW

DATA OUT-

 

 

 

 

 

 

 

 

BROWN

DATA IN+

 

 

 

 

 

 

 

 

RED

DATA IN-

 

 

 

 

 

 

 

 

GREEN

POWER ON/OFF SWITCH

 

 

 

 

BLUE

POWER ON/OFF SWITCH

 

 

 

 

BLACK

RADAR BATTERY GROUND

 

 

 

 

WHITE

RADAR BATTERY POSITIVE

 

 

 

 

BLUE

MOTOR SUPPLY-

 

 

 

 

 

 

 

 

RED

MOTOR SUPPLY+

 

 

 

 

Figure 2.6.1 - OPEN ARRAY Connections

NOTE

Radar Switch

Radar Switch

When installing a Open Array Radar, it is important to connect: a. Red (motor+) and White to B+ connection

b. Blue (motor -) and Black to B- connection.