EPX10 User Manual ◄ 15

Error indications on the unit:

“ERROR” led is lit.
- The temperature of the battery is over +55 °C/131°F
Action: Wait until the light goes out, when the tem-
perature drops you will be able to braze again.
“ERROR” led ashes.
- The temperature of the battery is below +10 °C/50°F
Action: Leave the unit on, the built-in heating ele-
ment will heat up the battery. Wait until light goes out
and the temperature has risen, and you will be able to
braze again.
“ERROR” and ”LOW BATTERY” led ashes.
- The temperature of the battery is below +10 °C/50°F
and the battery is almost discharged.
Action: Charge the batteries.
“ERROR” Led is lit after a braze.
- The pin brazing was not complete.
Action: The braze should be remade to achieve good
results. The Led turns off after 8 seconds.
“ERROR” Led glows.
- Failure of a sensor in the unit.
Action: The unit should be sent for repair.
”LOW BATTERY” Led ashes.
- Battery is almost discharged
”LOW BATTERY” led is lit.
- Battery is discharged. Charge the batteries.
NOTHING HAPPENS WHEN YOU PRESS THE
BUTTONS”
- The electronics may have gotten stuck.
Action: Remove control 5A fuse for a short time, put
it back again.
“THE BRAZING NEVER STOPS”
- The electronics may have gotten stuck.
Action: Remove the gun and the ground magnet from
the rails and disconnect them from the unit as soon as
possible. Remove the control 5A fuse, check that noth-
ing has been damaged before the fuse is put back.
TROUBLESHOOTING