FUNCTION

 

One time n/4 mm backfeed

 

 

<ESC>

“j”

 

CODE

 

n

 

 

1B

6A

n

HEX

 

REMARKS Feeds the paper back n/4mm once only.

The value of n is 1 to 255.

Space setting for one line is not changed.

This command can also feed the paper back to the page before the current page. In this case, the position of the line on the previous page is determined by the page length control.

FUNCTION

 

One time n/8 mm feed

 

 

<ESC>

“I”

 

CODE

 

n

 

 

1B

49

n

HEX

 

REMARKS Performs a line feed n/8mm once only.

The value of n is 1 to 255.

Space setting for lines is not changed.

FUNCTION

 

Set vertical tab stops

 

 

 

 

 

<ESC>

“B”

 

 

...

<0>

CODE

 

n1

n2

 

 

1B

42

n1

n2

...

00

HEX

 

REMARKS Cancels all current vertical tab stops and sets new vertical tab stops at lines n1, n2, etc., where n1, n2, etc. are numbers between 0 and 255. A maximum of 16 vertical tab stops can be set.

The tab stops must be specified in ascending order; any violation of ascending order terminates the tab stop list. Standard termina- tion is by the <0> control code.

The vertical tab stops are set in terms of the current line spacing and do not move if the line spacing is changed later.