112

APPENDIX
No. 1
DIP-SW1
2345678
No. 1
DIP-SW2
234
B-2. Serial Interface Type
ON ON
OFF OFF
DIP-SW 1
Switch 1-1 Switch 1-2 Command emulation
ON ON Star Line Mode
OFF ON Star Page Mode
ON OFF DP8340 Mode
OFF OFF ESC/POS Mode
The factory settings of DIP switch are all on.

The functions of switches 1-3 through 1-8 will change according to the command

emulation that has been set using switches 1-1 and 1-2.

(1) Star Line mode

Switch
Function ON OFF
1-1 Command emulation Always ON
1-2 Command emulation Always ON
1-3 Should not be changed (Should be set to on)
1-4 Sensor adjustment Invalid Valid
1-5 Should not be changed (Should be set to on)
1-6 Handshaking conditions Offline or receive Receive buffer full
(conditions for BUSY) buffer full
1-7 Automatic status back function Invalid Valid
1-8 Should not be changed (Should be set to on)

(2) Star Page mode

Switch
Function ON OFF
1-1 Command emulation Always OFF
1-2 Command emulation Always ON
1-3 Should not be changed (Should be set to on)
1-4 Sensor adjustment Invalid Valid
1-5 Should not be changed (Should be set to on)
1-6 Handshaking conditions Offline or receive Receive buffer full
(conditions for BUSY) buffer full
1-7 Automatic status back function Invalid Valid
1-8 Should not be changed (Should be set to on)