Large Volume Power Burner: Gas, Oil & Dual Fuel Commercial Water Heaters
■Limited Warranty Outline
–If the tank should leak any time during the first three years, under the terms of the warranty, State Water Heaters will repair or replace heater; installation, labor, handling and local delivery extra.
–NOTE: This Outline Is NOT A Warranty. For complete information, consult the written warranty or State Water Heaters.
■TPO – Oil Fired Models: No. 1 or 2 Oil
–
–Available for firing light fuel oils including diesel
–Oil ignition transformer
–Integral
–Squirrel cage blower
–Oil safety valve
■TPD – Dual Fuel Gas/Oil: Natural Gas or Propane & No. 1 or 2 Oil
–
–Gas electric pilot and gas ignition transformer
–Pilot and main pressure regulators
–Air safety switch
–Manual fuel selector switch
–Integral
–Squirrel cage blower
■Meets or exceeds current edition of
■Low NOX – TPX Low NOX models meet or exceed current Texas and California SCAQMD air quality standards.
■UL – Entire unit UL listed (File No. MH11631).
■
■ASME Construction Standard – 160 PSI working pressure on all models.
■Powered Gas Burner – Powered burner has electronic flame safeguard control with intermittent spark ignition. Also included are main and pilot automatic gas valves plus gas pressure regulators, diaphragm air switch for proof of blower operation.
–TPX Low NOX Models are factory standard with modulating fire. The burner automatically adjusts the firing rate and the Btu output to maintain precise system temperature control.
■Fully Automatic Controls With Safety Shutoff – High temperature limit control (manual reset). ASME rated temperature and pressure relief valve. Hinged door control compartment for ease of access. Two thermostats, upper and lower, for accurate temperature control. Standard control is for 120˚F - 180˚F water service.
■Jacket And Insulation – Heavy gauge steel with baked powder coat finish. Insulated with
■Professional
■Other Features
–Two layers of high temperature ceramic fiber insulation in combustion chamber
–Flame inspection port opening
–Mounted on rugged channel iron skids
–Combination temperature and pressure gauge
–Low water cutoff
–ASME rated temperature and pressure relief valve
–Barometric draft regulator
–Two cleanout inspection openings
–120 volt control circuit
–Drain valve
–Removable lifting lugs
■Options
–Factory Mutual approved control arrangement
–Industrial Risk Insurance (IRI Gas Train)
–5 year or 10 year limited warranty
–High or low water pressure switch
–180°F water service thermostats
–A.G.A. rated T & P Valve
–Modular graphic burner systems management on heaters with 270,000 Btu input and over
–Combustion Air intake Adapter
COMMERCIAL 500 Lindahl Parkway, Ashland City, TN 37015 • www.statewaterheaters.com
The Expert’s Choice®