State Industries Gas warranty Specifications, The Expert’s Choice

Models: Oil & Dual Fuel Commercial Water Heaters Gas

1 6
Download 6 pages 39.94 Kb
Page 2
Image 2
SPECIFICATIONS

TPG Power Gas Large Volume Commercial Water Heaters

SPECIFICATIONS

 

Nominal

Input

 

Output (Gallons)

 

 

 

 

 

 

 

 

 

 

Ship.

 

 

 

Model Number

Storage

Rating

 

 

 

 

 

 

 

Dimensions In Inches

 

 

 

Wt.

 

 

Motor HP

Capacity

BTU/Hr.

First

 

Recovery

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

w/Burner

 

 

120V 60 Hz 1

 

U.S.

Natural

Hour

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(lbs.)

 

 

 

 

Gallons

Gas

Rating

80°F Rise

100°F Rise

140°F Rise

A

B

C

D

E

F

G

H

J

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TPG 150 140 NEA

150

140,000

256

170

136

97

8312

14

12

2734

114

3612

5

47

73

1292

 

 

 

TPG 150 199 NEA

150

199,000

313

241

193

138

8312

14

12

2734

114

3612

6

47

73

1292

17 HP - 2.5 Amps

TPG 150 255 NEA

150

255,000

367

359

247

176

8312

14

12

2734

114

3612

6

47

73

1292

 

 

 

TPG 150 270 NEA

150

270,000

382

327

262

187

8312

14

1

2734

114

3612

6

5712

73

1397

 

 

 

TPG 150 400 NEA

150

400,000

507

485

387

277

8312

14

1

2734

114

3612

7

5712

73

1397

14 HP - 4.6 Amps

TPG 150 540 NEA

150

540,000

644

654

524

374

8312

14

1

2734

114

3612

8

5712

73

1505

 

 

 

TPG 150 720 NEA

150

720,000

818

873

698

499

8312

14

114

2734

114

3612

10

5712

73

1510

13 HP - 5.5 Amps

TPG 200 300 NEA

200

300,000

451

364

291

208

8312

15

1

3212

112

4434

6

6612

73

2098

1

4

HP - 4.6 Amps

TPG 200 600 NEA

200

600,000

742

727

582

416

8312

15

1

3212

112

4434

8

6612

73

2098

 

TPG 200 800 NEA

200

800,000

936

970

776

554

8312

15

114

3212

112

4434

10

6612

73

2103

1

3

HP - 5.5 Amps

TPG 200 1000 NEA

200

1,000,000

1130

1212

970

693

8312

15

114

3212

112

4434

10

6612

73

2103

 

TPG 200 1250 NEA

200

1,250,000

1372

1515

1212

866

8312

15

114

3212

112

4434

12

6612

73

2467

1

2

HP - 7.4 Amps

TPG 200 1500 NEA

200

1,500,000

1615

1818

1455

1039

8312

15

112

3212

112

4434

12

8112

73

2757

 

TPG 300 300 NEA

300

300,000

531

364

291

208

9112

14

1

2612

112

4434

6

6612

83

2150

1

4

HP - 4.6 Amps

TPG 300 600 NEA

300

600,000

822

727

582

416

9112

14

1

2612

112

4434

8

6612

83

2150

 

TPG 300 800 NEA

300

800,000

1016

970

776

554

9112

14

114

2612

112

4434

10

6612

83

2308

1

3

HP - 5.5 Amps

TPG 300 1000 NEA

300

1,000,000

1210

1212

970

693

9112

14

114

2612

112

4434

10

6612

83

2308

 

TPG 300 1250 NEA

300

1,250,000

1452

1515

1212

866

9112

14

114

2612

112

4434

12

6612

83

2584

1

2

HP - 7.4 Amps

TPG 300 1500 NEA

300

1,500,000

1695

1818

1455

1039

9112

14

112

2612

112

4434

12

8112

83

2774

 

TPG 400 600 NEA

400

600,000

902

727

582

416

9112

15

1

3212

2

55

8

7612

81

3207

14 HP - 4.6 Amps

TPG 400 800 NEA

400

800,000

1096

970

776

554

9112

15

114

3212

2

55

10

7612

81

3212

 

 

 

TPG 400 1000 NEA

400

1,000,000

1290

1212

970

693

9112

15

114

3212

2

55

10

7612

81

3212

13 HP - 5.5 Amps

TPG 400 1250 NEA

400

1,250,000

1532

1515

1212

866

9112

15

114

3212

2

55

12

7612

81

3212

 

 

 

TPG 400 1500 NEA

400

1,500,000

1775

1816

1455

1039

9112

15

112

3212

2

55

12

9112

81

3402

 

 

 

TPG 400 1750 NEA

400

1,750,000

2017

2121

1697

1212

9112

15

2

3212

2

55

14

9112

81

3528

12 HP - 7.4 Amps

TPG 400 2000 NEA

400

2,000,000

2259

2424

1939

1385

9912

15

2

3212

2

55

14

9112

89

3669

 

 

 

TPG 500 2250 NEA

500

2,250,000

2582

2727

2182

1558

110

15

2

3212

2

55

16

9112

100

4277

34 HP - 10.2 Amps

TPG 500 2500 NEA

500

2,500,000

2824

3030

2424

1732

110

15

2

3212

2

55

16

9112

100

4419

 

 

 

TPG 600 720 NEA

600

720,000

1178

873

698

499

119

15

114

3212

2

55

10

7612

109

3667

 

 

 

TPG 600 1000 NEA

600

1,000,000

1450

1212

970

693

119

15

114

3212

2

55

10

7612

109

3667

13 HP - 5.5 Amps

TPG 600 1250 NEA

600

1,250,000

1692

1515

1212

866

119

15

114

3212

2

55

12

7612

109

3667

 

 

 

TPG 600 1500 NEA

600

1,500,000

1935

1816

1455

1039

119

15

112

3212

2

55

12

9112

109

3837

 

 

 

TPG 600 1750 NEA

600

1,750,000

2177

2121

1697

1212

119

15

2

3212

2

55

14

9112

109

3837

12 HP - 7.4 Amps

TPG 600 2000 NEA

600

2,000,000

2419

2424

1939

1385

119

15

2

3212

2

55

14

9112

109

3837

 

 

 

TPG 600 2250 NEA

600

2,250,000

2662

2727

2182

1558

119

15

2

3212

2

55

16

9112

109

4477

34 HP - 10.2 Amps

TPG 600 2500 NEA

600

2,500,000

2904

3030

2424

1732

119

15

2

3212

2

55

16

9112

109

4619

 

 

 

Certified Minimum Installation Clearances to Combustibles:

Front: 18 inchesASME

Back: 0 inches

Sides: 0 inches

Top: 5 inches

A clearance of 24 inches should be maintained from serviceable parts such as relief valve, power burner, drain valve and anodes (anodes are located on side above cold water inlet).

Minimum gas supply pressure: 7 Inches W.C.

Maximum gas supply pressure: 13 Inches W.C.

TPG models are Category I appliances (Fan Assisted) and require a negative draft. These units should only be commonly vented with other Category I negative draft appliances per the latest addition of the National Fuel Gas Code. An approved/listed Type “B” venting material is recommended. A negative draft of -0.02˝ to -0.07 is required in the vent.

TPG models are available in both natural gas and propane. To order propane, change the “N” to “P” in the model number. Example: TPG 150 140 PEA

Manual background COMMERCIAL 500 Lindahl Parkway, Ashland City, TN 37015 • www.statewaterheaters.com

The Expert’s Choice®

Page 2
Image 2
State Industries Gas, Oil & Dual Fuel Commercial Water Heaters warranty Specifications, The Expert’s Choice