TROUBLESHOOTING FLOWCHART

APPLY POWER TO

APPLIANCE

REQUEST NO FOR HEAT PRESENT?

YES

 

 

 

 

 

 

 

 

 

IS

NO

WAIT FOR PRESSURE

PRESSURE SWITCH

SWITCH TO OPEN

PROVEN OPEN WITHIN

 

 

 

DISPLAY ERROR

 

 

 

5 SECONDS?

 

 

 

NUMBER 7

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COMBUSTION

 

 

 

 

 

FAN ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IS

 

 

 

 

 

PRESSURE SWITCH

NO

WAIT FOR PRESSURE

PROVEN CLOSED

 

 

 

SWITCH TO CLOSE

 

 

 

DISPLAY ERROR

WITHIN 5

 

 

 

 

 

 

NUMBER 6

SECONDS?

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ISNO

PRESSURE SWITCH

PROVEN OPEN WITHIN

5SECONDS?

YES

3 MINUTE

AUTOMATIC RESET

TIME DELAY

WAIT FOR PRESSURE

SWITCH TO OPEN

DISPLAY ERROR

NUMBER 7

ONE HOUR

AUTOMATIC RESTART

TIME DELAY

PREPURGE

COMBUSTION FAN

OFF

IS

NO

TURN OFF

COMBUSTION FAN,

IGNITOR

 

 

 

DISPLAY ERROR CODE

 

 

 

OKAY?

 

 

 

NUMBER 8

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IGNITOR ON FOR

 

 

 

 

WARM-UP TIME

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TURN OFF

 

 

COMBUSTION FAN

COMBUSTION

 

AFTER POST-PURGE

FAN OFF

 

DISPLAY ERROR 3

GAS VALVE OPENS

COMBUSTION FAN

ON

MAIN

BURNER LIGHTS NO

LESS

YES

YES

WAIT FOR PRESSURE

 

NO

 

IS

SWITCH TO CLOSE

 

 

 

PRESSURE SWITCH

 

 

 

PROVEN CLOSED

DISPLAY ERROR

 

 

 

 

 

 

WITHIN 5

NUMBER 6

 

 

 

 

 

 

SECONDS?

 

 

 

 

 

 

 

AND IS SENSED DURING TRIAL FOR

IGNITION

GAS VALVE CLOSES

THAN 3 TRIES FOR IGNITION?

INTERPURGE

YES

IGNITOR TURNS OFF

ISYES

FLAME SENSE LOST?

NO

GAS VALVE CLOSES

NO

 

 

LOST

YES

 

LESS THAN 4

 

 

 

 

TIMES?

 

 

 

 

 

NO

 

 

 

 

 

 

 

 

IS

NO

WAIT FOR PRESSURE

 

 

PRESSURE SWITCH

 

 

PROVEN CLOSED

 

 

 

SWITCH TO CLOSE

 

 

 

 

 

DISPLAY ERROR

 

 

WITHIN 5

 

 

 

 

 

 

 

 

NUMBER 6

 

 

SECONDS?

 

 

 

 

 

YES

 

 

 

 

 

 

IS

YES

 

 

 

REQUEST FOR HEAT

 

 

 

GAS VALVE OFF

 

NO

 

 

 

 

SATISFIED?

 

 

 

 

 

 

Please Note:

 

The control continually monitors

 

internal circuits and external sensors.

 

Error codes noted above, and those for

COMBUSTION FAN

self-diagnostic faults can be found on

OFF AFTER POST-

pages 30 through 32.

PURGE DELAY

33

Page 33
Image 33
State Industries GP 6 50YPC T 100, GP 6 40YPC T 100, 317998-002 installation instructions Troubleshooting Flowchart, Yes

317998-002, GP 6 50YPC T 100, GP 6 40YPC T 100 specifications

State Industries has long been at the forefront of technological advancements and innovative design in the industrial market. The company has developed a range of high-efficiency products designed for various applications, including the GP 6 40YPC T 100 and GP 6 50YPC T 100 models, as well as the 317998-002 component. Each product in this lineup is characterized by specific features and cutting-edge technologies tailored to meet diverse operational needs.

The GP 6 40YPC T 100 model boasts a robust construction aimed at durability and resilience in demanding environments. Its design incorporates advanced materials that resist wear and corrosion, ensuring a prolonged lifespan and reduced maintenance requirements. The model operates efficiently even in high-pressure scenarios, making it suitable for various industrial applications, including manufacturing and processing.

In contrast, the GP 6 50YPC T 100 model is designed with a focus on maximizing performance and energy efficiency. It features an optimized airflow system that enhances heat dissipation, preventing overheating and maintaining operational integrity. This model is ideal for applications that require continuous operation, as it minimizes downtime and maximizes productivity. Additionally, the GP 6 50YPC T 100 is equipped with smart technology that monitors performance metrics, providing real-time feedback on operational efficiency.

The 317998-002 component serves as a critical element in both models, acting as a versatile interface that integrates seamlessly with existing systems. It is designed to enhance connectivity and facilitate communication between various industrial components, promoting improved efficiency and ease of integration.

Both the GP 6 models and the 317998-002 feature user-friendly interfaces, allowing operators to easily manage and adjust settings. This focus on user experience helps to reduce training time and improve overall operational efficiency. Furthermore, both models adhere to strict industry standards, ensuring reliability and safety in all conditions.

In summary, State Industries' GP 6 40YPC T 100 and GP 6 50YPC T 100 models, along with the 317998-002 component, represent the pinnacle of innovation and reliability in industrial solutions. Their advanced features, technologies, and characteristics make them suitable choices for organizations looking to enhance productivity and operational efficiency in a variety of applications. With a commitment to quality and performance, State Industries continues to set the standard for excellence in the industry.