State Industries 317998-002 Replacing the Flame Sense/Hot Surface igniter Assembly

Models: 317998-002 GP 6 50YPC T 100 GP 6 40YPC T 100

1 40
Download 40 pages 9 Kb
Page 26
Image 26

Replacing the Flame Sense/Hot Surface igniter Assembly

1.Remove the manifold/burner assembly. See Removing the Manifold/Burner Assembly.

2.Lift the retainer clip straight up from the back of the manifold component block (using a flat-blade screwdriver), then remove the manifold component block from the manifold door (Figure 26.)

3.Remove and keep the screw securing the flame sense/ hot surface igniter assembly (Figure 26)

4.Remove and discard the old flame sense/hot surface igniter assembly.

5.Route the new flame sense/hot surface igniter con- nector wire through manifold/burner door opening as shown in figure 26. Secure assembly to bracket using screw removed earlier.

Screw

Retainer Clip

Cleaning the Combustion Chamber and Air Diverter Assembly

1.Follow procedure outlined in “Removing the Manifold/ Burner Assembly”.

2.Use a vacuum cleaner/shop vac to remove all loose debris in the combustion chamber (Figure 28). Use compressed air to clear any dust or debris that may have accumulated on the air diverter assembly.

Air Diverter

Combustion

Assembly

Chamber

Manifold

Door Gasket

FIGURE 28.

3.Reassemble following the procedure under “Replacing the Manifold/Burner Assembly”

Manifold Component

Block

Flame Sense/

Hot Surface

Igniter Assembly

Replacing the Manifold/Burner Assembly

WARNING

FIGURE 26.

6.Reposition the manifold component block in the mani- fold door opening and secure it with the retainer clip.

7.See Replacing the Manifold/Burner Assembly.

External Inspection & Cleaning of the Air Intake Chamber Screen

1.At least twice annually inspect the air intake chamber screen (Figure 27) for any dust or debris that may have accumulated on the louvers. NOTE: If the water heater is located in an area that is subjected to lint and dirt, it may be necessary to check the air intake chamber

screen more frequently.

2. Use a vacuum cleaner with a hose attachment to remove any dust or debris that may have accumulated on the screen.

Air Intake Chamber

Screen

FIGURE 27.

Explosion Hazard

Remove any fiberglass between gasket and combustion chamber.

Replace viewport if glass is missing or damaged.

Replace two piece wire connector if missing or removed.

Replace door gasket if damaged.

Tighten both manifold door screws securely.

Failure to follow these instructions can result in death, explosion, or fire.

1.Check the door gasket for damage or imbedded debris prior to installation.

2.Inspect the view port for damage and replace as required.

26

Page 26
Image 26
State Industries 317998-002 Replacing the Flame Sense/Hot Surface igniter Assembly, Replacing the Manifold/Burner Assembly

317998-002, GP 6 50YPC T 100, GP 6 40YPC T 100 specifications

State Industries has long been at the forefront of technological advancements and innovative design in the industrial market. The company has developed a range of high-efficiency products designed for various applications, including the GP 6 40YPC T 100 and GP 6 50YPC T 100 models, as well as the 317998-002 component. Each product in this lineup is characterized by specific features and cutting-edge technologies tailored to meet diverse operational needs.

The GP 6 40YPC T 100 model boasts a robust construction aimed at durability and resilience in demanding environments. Its design incorporates advanced materials that resist wear and corrosion, ensuring a prolonged lifespan and reduced maintenance requirements. The model operates efficiently even in high-pressure scenarios, making it suitable for various industrial applications, including manufacturing and processing.

In contrast, the GP 6 50YPC T 100 model is designed with a focus on maximizing performance and energy efficiency. It features an optimized airflow system that enhances heat dissipation, preventing overheating and maintaining operational integrity. This model is ideal for applications that require continuous operation, as it minimizes downtime and maximizes productivity. Additionally, the GP 6 50YPC T 100 is equipped with smart technology that monitors performance metrics, providing real-time feedback on operational efficiency.

The 317998-002 component serves as a critical element in both models, acting as a versatile interface that integrates seamlessly with existing systems. It is designed to enhance connectivity and facilitate communication between various industrial components, promoting improved efficiency and ease of integration.

Both the GP 6 models and the 317998-002 feature user-friendly interfaces, allowing operators to easily manage and adjust settings. This focus on user experience helps to reduce training time and improve overall operational efficiency. Furthermore, both models adhere to strict industry standards, ensuring reliability and safety in all conditions.

In summary, State Industries' GP 6 40YPC T 100 and GP 6 50YPC T 100 models, along with the 317998-002 component, represent the pinnacle of innovation and reliability in industrial solutions. Their advanced features, technologies, and characteristics make them suitable choices for organizations looking to enhance productivity and operational efficiency in a variety of applications. With a commitment to quality and performance, State Industries continues to set the standard for excellence in the industry.