MULTI FLUE - (2 UNITS) WITH HORIZONTAL STORAGE TANK

WARNING: THIS DRAWING SHOWS SUGGESTED

PIPING CONFIGURATION AND OTHER DEVICES;

CHECK WITH LOCAL CODES AND ORDINANCES

FOR ADDITIONAL REQUIREMENTS.

HOT WATER TO FIXTURES

LEGEND

TEMPERATURE & PRESSURE

RELIEF VALVE

PRESSURE RELIEF VALVE

CIRCULATING PUMP

TANK TEMPERATURE CONTROL

DRAIN

FULL PORT BALL VALVE

CHECK VALVE

TEMPERATURE GAGE

WATER FLOW SWITCH

40

 

 

HOT WATER

 

 

RETURN FROM

PIPE T&P TO

PIPE T&P TO

FIXTURES

ALTERNATE

OPEN DRAIN

OPEN DRAIN

LOCATION

 

 

 

 

COLD WATER

 

 

SUPPLY

FINISHED

 

EXPANSION

 

TANK

FLOOR

 

 

 

NOTES:

1.Preferred piping diagram.

2.The temperature and pressure relief valve setting shall not exceed pressure rating of any component in the system.

3.Service valves are shown for servicing unit. However, local codes shall govern their usage.

4.The Tank Temperature Control should be wired to and control the pump between the water heater(s) and the storage tank(s).

5.The water heater’s operating thermostat should be set 5 degrees F higher than the Tank Temperature Control.

Page 40
Image 40
State Industries SBL85 390NE(A), SBL85 275NE(A), SBL95 199NE instruction manual Return from