The following are fault conditions related to the ignition module: Fault: I.M. IGNITER

There is a problem with the ignition module

Fault: I.M. LOCK OUT

I.M Failed an internal hardware or software check

Possible Cause

Remedy

 

 

1. Ignition Module Failure

1. Replace Ignition Module

 

 

Fault: I.M. PS CLOSED

The pressure switch is stuck closed

 

Possible Cause

 

Remedy

1.

Pressure switch is shorted

1.

Check and replace wiring

 

or not wired properly

 

 

2.

Defective pressure switch

2.

Replace pressure switch

 

 

 

Fault: I.M. PS OPEN

 

 

The pressure switch is stuck open

 

 

 

 

 

 

Possible Cause

 

Remedy

 

 

 

 

1.

Pressure switch is not

1.

Check that the pressure

 

connected

 

switched is wired properly

2.

Pressure switch is open or

2.

Check and repair wiring

 

not wired properly

 

 

3.

Defective pressure switch

3.

Replace pressure switch

4.

Insufficient pressure

4.

Verify blower operation

 

developed by combustion

 

to the ignition module

 

blower

 

 

 

 

 

 

Fault: I.M. ECO

Emergency cut-off, water temperature has reached an unsafe temperature

 

Possible Cause

 

Remedy

 

 

 

 

1.

Temperature probe is

1.

Check that the temperature

 

damaged

 

probe is not damaged and

 

 

 

replace probe if necessary

2.

Temperature probe wiring

2.

Check and repair wiring

 

is damaged

 

 

3.

Water in tank too hot

3.

Normal condition when

 

 

 

water temperature exceeds

 

 

 

safety limit. Allow water

 

 

 

to cool or admit water into

 

 

 

tank and manually reset the

 

 

 

control. Determine cause

 

 

 

for over temp condition

 

 

 

 

Fault: I.M. 115V REVERSED

The line hot and the neutral line are reversed wired

 

Possible Cause

Remedy

1.

Line hot and neutral

1. Check wiring and reverse

 

reversed

line hot and neutral

 

 

Fault: I.M. LOW FLAME

 

Low flame has been sensed

 

 

Possible Cause

Remedy

1.

Weak or insufficient flame

1. Check flame rod

 

detected

 

 

Possible Cause

 

Remedy

 

 

 

 

1.

Igniter is not wired in or

1.

Check that the igniter is

 

the wiring is damaged

 

wired in properly or that

 

 

 

the wiring is not damaged

2.

Igniter is damaged

2.

Replace igniter

3.

The ignition module is

3.

Replace ignition module

 

damaged

 

 

 

 

 

 

Fault: I.M. FLAME FAULT

A flame was detected when there is not supposed to be a flame (no call for heat).

 

Possible Cause

Remedy

 

 

 

1.

Flame sense wiring is

1. Check and repair wiring

 

damaged

 

2.

Ignition module is

2. Replace ignition module

 

damaged

 

 

 

 

PRIOR TO START UP

REQUIRED ABILITY

INSTALLATION OR SERVICE OF THIS WATER HEATER REQUIRES ABILITY EQUIVALENT TO THAT OF A LICENSED TRADESMAN IN THE FIELD INVOLVED. PLUMBING, AIR SUPPLY, VENTING, GAS SUPPLY AND ELECTRICAL WORK ARE REQUIRED.

Before attempting start-up, thoroughly study and familiarize yourself with the exact sequence of operation and all other details on the specific heater being used.

The power burner is equipped with an ignition system which automatically sequences prepurge and ignition, senses and ignites main burner flame and sequences burner operation. Heater is equipped with an ignition control which locks out after three unsuccessful ignition attempts. Familiarize yourself with the sequence of operation of this unit prior to start-up.

Be certain that the water heater is full of water, that air is purged from all lines, there are no leaks (gas and water), and all inlet water lines are open.

The following test equipment should be on hand (all test equipment must be acclimated to ambient temperature before calibration and use.)

Two U-tube manometers or calibration 0-10" (0-2.5 kPa) and 0-35" (0-2.5 kPa) W.C. pressure gauges.

Attach a gas pressure gauge or manometer to the upstream side of main gas cock and a gas pressure gauge or manometer to the manifold pressure tap.

You are now ready to begin the burner start-up procedure.

22

Page 22
Image 22
State Industries SRT80 120NE warranty Prior to Start UP, Required Ability

SRT80 120NE specifications

The State Industries SRT80 120NE is a high-efficiency water heater designed for both residential and commercial applications. It stands out in the market due to its advanced features and reliable performance, making it an excellent choice for users seeking durability, efficiency, and convenience.

One of the key features of the SRT80 120NE is its robust tank construction. It is built with a strong glass-lined steel tank to enhance durability while reducing the likelihood of corrosion over time. The insulation surrounding the tank minimizes heat loss, ensuring that the water remains hot for longer periods, ultimately leading to energy savings.

The SRT80 120NE utilizes a state-of-the-art heating element system, which offers rapid recovery rates. This means that you can enjoy a continuous supply of hot water, even during peak usage times. The heating elements are also designed for easy replacement, providing a cost-effective solution for maintenance.

Another noteworthy feature is the advanced control system that allows for precise temperature adjustments. This ensures that users can select their desired water temperature with ease, enhancing comfort and convenience. Additionally, the built-in safety features such as a temperature and pressure relief valve help to prevent potential hazards, ensuring user safety.

In terms of energy efficiency, the State Industries SRT80 120NE boasts impressive energy factor ratings. This translates to lower energy bills and a reduced environmental footprint, making it an eco-friendly option for users. Additionally, the unit meets or exceeds various energy efficiency standards, underscoring its commitment to sustainability.

The SRT80 120NE also incorporates innovative technologies such as electronic controls and diagnostics, which facilitate easier troubleshooting and repair. This ensures that any issues can be addressed quickly, reducing downtime and providing peace of mind.

Moreover, the compact design of the SRT80 120NE makes it suitable for installation in various locations, even where space is at a premium. With a variety of connections and compatibility with numerous plumbing setups, installation becomes straightforward, allowing for flexibility in use.

In summary, the State Industries SRT80 120NE combines robust construction, advanced heating technology, and superior efficiency, making it an ideal choice for those needing reliable hot water solutions. Whether for residential or commercial use, this water heater stands out for its performance and convenience.