Sterling SDA Series 25-100 15 cfm Determining Temperature Controller Errors or Sensor Errors

Models: 30 cfm

1 50
Download 50 pages 57.96 Kb
Page 39
Image 39

Alarm Message

Cause

Corrective Action

Dryer Status

 

 

 

 

VALVE MTR

The limit switch on the

Limit switch may be out of

- Dryer Shuts down:

 

valve may not have

position. Re-adjust the

- Process blower OFF.

 

been wired correctly.

switch to make sure it trips

- Process heaters OFF.

 

The valve has made

when it is at the high

- Regen heaters OFF.

 

enough rotations and

position, and it does not

- Alarm light is ON

 

the correct position of

touch the cam when it is at

- Alarm horn is ON.

 

the valve was not

the low position.

 

 

detected.

The switch is indicating the

 

 

 

incorrect desiccant tank is in

 

 

 

regeneration. Check the

 

 

 

wiring of the switch against

 

 

 

the wiring diagram. Make

 

 

 

sure all the wire connections

 

 

 

are tight.

 

 

 

Limit switch may be faulty.

 

 

 

Replace the switch and

 

 

 

make sure the wires are

 

 

 

connected correctly.

 

6-2 Determining Temperature Controller Errors or Sensor Errors

Using a Thermocouple

If the controller displays a temperature that is close to room temperature (70ºF/21ºC) when you short-circuit controller input terminals, the controller is normal and the sensor is probably broken, short-circuited, or incorrectly wired.

Other service problems or questions can be answered by contacting the Service Department.

15, 30, & 60 cfm Compact Dryers

39

Page 39
Image 39
Sterling SDA Series 25-100 15 cfm Determining Temperature Controller Errors or Sensor Errors, Valve Mtr, Alarm Message