Hopper temp Target

Enter the drying temperature for the drying hopper.

Hopper temp Act.

The current temperature at the feed opening of hopper flap will be displayed.

&If the unit operates with motor flaps (optional):

Granule Temp

Enter the material temperature at which the flap on the drying hopper should close.

&This value is entered in percent of the temperature on the hopper inlet.

The material temperature calculated by the control system for closing the flap on the drying hopper is displayed

Drying time Target

Displaying trend

Temperature

Enter the dwelling time of the material within the drying hopper in minutes.

F

&

Observe the indicated dwelling time.

When the drying hopper is released, the dwelling time starts. The residual time is displayed (= current dwelling time).

If the drying hopper is blocked, the current dwelling time is reset to the value of the dwelling time which has been entered before.

Drying time Act

The dwelling time of the material in the drying hopper is displayed in minutes.