8.3. Electrical Connection

SDF 250/400/500

8.3. Electrical Connection

￿Observe the rules of the local electricity board.

Check that the supply voltage and the power frequency are in accordance with the data on the nameplate of the device.

The electrical connection may only be carried through or assigned by Sterling service staff or by qualified staff authorized by Sterling.

Other persons are not permitted to carry through the electrical connection.

The main switch must be freely accessible.

Ground the equipment against electrostatic charging.

FRegularly make sure that none of the electrical or screw connections are loose.

Make sure that the main switch is at “0" position before the electrical connection is carried out.

The operating voltage is 400 V +/- 10%, 3 AC, 50 Hz

Special voltages can be supplied on request.