| SDF 250/400/500 |
5.1. Maintenance schedule | |
Daily: | Check warning signs on equipment for good legibility and completeness |
| Clean return air filters and casing (depending on dust |
Weekly: | Check main switch for proper function |
| Check the signal lamps for proper functioning |
Every three months: | Clean filter of the regeneration blower (depnding on amount of dust |
| collected) |
Every six months: | Change return air filters (depending on dust |
| Clean air filter of the suction box |
| All electrical and mechanical connections should be checked to see if |
| they fit securely |
Annually: | Dewpoint should be checked (only by Sterling service personnel) |
Whenever the |
|
material is changed: | The drying hopper and suction box must be cleaned |
&The service intervals refer to a
FThe given maintenance intervals are average values.
Check whether in your individual case the maintenance intervals must be shortened.