Sterling Plumbing SP1500D Series manual Install the Strike Expander Jamb, Install the Fixed Panel

Models: SP1500D Series

1 52
Download 52 pages 2.55 Kb
Page 13
Image 13

Install the Strike Expander Jamb

Strike Jamb

Expander

Jamb

Wall Jamb

#10-16 x 3/8" Panhead Screw

View from Inside Shower

12. Install the Strike Expander Jamb

Install the Fixed Glass

Sealant

Fixed Panel

U-Channel

Sealant

Inside of Shower

Position the expander jamb in the strike jamb.

Align the holes in the expander jamb with the slots in the strike jamb.

Plumb the expander jamb with a level.

Secure with three #10-16 x 3/8″ panhead screws.

13. Install the Fixed Panel

Slide the U-Channel approximately 3/16″ (5 mm) into the pivot jamb.

Apply a bead of caulk into the entire length of the groove in the pivot jamb.

Apply a bead of caulk in the U-Channel.

NOTE: The fixed glass panel is the narrow panel.

IMPORTANT! The textured side of the glass should be positioned to the outside of the shower.

Carefully lift the narrow fixed glass panel into the outer channel in the top track and the U-Channel at the bottom.

Press the fixed panel gently into the groove in the pivot jamb.

Sterling

13

1034026-2-D

Page 13
Image 13