Sterling Plumbing SP1500D Series manual Install the Door Panel

Models: SP1500D Series

1 52
Download 52 pages 2.55 Kb
Page 15
Image 15

Install the Door Panel

Top Track (Front Side)

Pivot Block

#8-32 x 1-1/8" Bolt

Top Track

(Front Side)

#8 Locknut

16. Install the Door Panel

Lift the door panel and insert the projecting bolt into the bushing in the bottom track.

Slide the pivot block into the top track.

Tilt the door panel and slide the pivot block until the projecting bolt at the top of the door slides into the larger hole in the pivot block.

Slide the pivot block and door panel so that the door panel closes with approximately 1/8″ (3 mm) clearance from the face of the expander jamb.

From above, insert a #8-32 x 1-1/8″ bolt through the center hole in the top track, and through the small hole in the pivot block.

NOTE: Thread the larger, all metal side of the locknut onto the bolt first.

Thread the lock nut onto the #8-32 x 1-1/8″ bolt and tighten with 1/4″ and 11/32″ wrenches.

Make sure the bottom of the door does not rub on the hollow seal in the bottom track. If necessary loosen the top pivot bolt with the provided open-end wrench.

Reposition the door and tighten the bolt.

If the door does not align with the expander jamb, loosen the screws holding the expander jamb and align it with the door.

Sterling

15

1034026-2-D

Page 15
Image 15
Sterling Plumbing SP1500D Series manual Install the Door Panel