A.SPIGOT SWITCH
The SPIGOT switch will automatically actuate the auger drive and refrigeration systems when the spigot is opened to dispense product. When the spigot is closed, the drive motor and compressor will remain "on" until the product in the barrel reaches the proper temperature.
B.
The
C.PUSH TO FREEZE SWITCH
The PUSH TO FREEZE switch is a "snap" switch used to start the freezing cycle. During initial freeze down, the
NOTE
After the gearmotor starts, there is a 3 second delay before the compressor starts.
Duringthenormaloperation,theredPUSHTOFREEZE switch light will illuminate after the freezer has been idle for the preset cycles. Before drawing product, press the PUSH TO FREEZE switch if it is illuminated. Wait until the green light is illuminated before dispens- ing.
NOTE
If the freezer shuts off and the PUSH TO FREEZE light flashes, you have an error condition. Turn the
D.GREENLIGHT
The green light is used to indicate that the product has reached the proper temperature and is ready to be dispensed.
NOTE
If the PUSH TO FREEZE red light is illuminated, push the PUSH TO FREEZE switch and wait until the green light illuminates before dispensing.
E.CLEAN SWITCH
The CLEAN switch is a "snap" switch. When the switch is pushed the refrigeration system will be OFF and the auger will rotate for cleaning. When the switch is pushed again, the auger will stop and the CLEAN light will flash indicating the freezer is in the CLEAN mode. To exit the CLEAN mode turn the
F.DRIVE MOTOR OVERLOAD
The internal DRIVE MOTOR OVERLOAD will trip if the drive motor is overloaded. It will reset after approxi- mately
G.RED MIX LOW LIGHT
The red MIX LOW light is designed to alert the operator to a low mix condition. The light will illuminate with approximately one gallon of mix in the hopper. When the MIX LOW light is illuminated, refill hopper immedi- ately.
NOTE
Failure to refill hopper immediately may result in operational problems.
H.HOLD READY SWITCH
The HOLD READY switch is a push button switch. When pushed in and held for 5 seconds, the hold ready mode will be activated. The product will remain ready to serve and the freezer will not go to idle. To return to normal operation push and hold for 5 seconds.
I.DISPENSERATEADJUSTER
The dispense rate adjuster limits the opening of the spigot. To adjust product dispense rate, turn the adjusting knob clockwise for slower flow and counter- clockwise for faster flow.
3.3 SANITIZING
Sanitizing must be done after the freezer is cleaned and just before the hopper is filled with mix. Sanitizing the night before is not effective. However, you should always clean the freezer and parts after using it.
WARNING
THE UNITED STATES DEPARTMENT OF AGRICULTURE AND THE FOOD AND DRUG ADMINISTRATION REQUIRE THAT ALL CLEANING AND SANITIZING SOLUTIONS USED WITH FOOD PROCESSING EQUIPMENT BE CERTIFIED FOR THIS USE.
When sanitizing the freezer, refer to local sanitary regulations for applicable codes and recommended sanitizing products and procedures. The frequency of sanitizing must comply with local health regulations. Mix sanitizer according to manufacturer's instructions to provide a 100 parts per million strength solution. Mix sanitizer in quantities of no less than 2 gallons (7.5 liters) of 120°F water. Allow sanitizer to contact the surfaces to be sanitized for 5 minutes. Any sanitizer must be used only in accordance with the manufacturer's instructions.
NOTE
Stoelting, Inc. has found that
8