Product does not

1. No mix in hopper.

1. Fill hopper with mix.

dispense.

2.

Mix inlet regulator tube is plugged.

2.

Unplug, using small sanitized brush.

 

3.

Special mix inlet regulator

3.

Order special mix inlet regulator.

 

 

needed for mix being used.

 

 

 

4. Drive motor overload tripped.

4. Automatic reset. Wait 15 to 30 minutes.

 

5.

Drive belt failure.

6.

Replace drive belt.

 

6.

Freeze-up. (Auger will not turn.)

7.

Turn OFF-ON switch to OFF for 15 minutes,

 

 

 

 

then restart.

 

 

 

Drive belt slipping or

1. Worn drive belt.

1. Call distributor for service.

squealing.

2.

Freeze-up (Auger will not turn).

2.

Turn OFF-ON switch to OFF for 15

 

 

 

 

minutes, then restart.

 

 

 

Low overrun.

1. Mix inlet regulator missing.

1. Replace mix inlet regulator.

 

2.

Mix inlet regulator "O"ring missing

2.

Replace mix inlet regulator "O" ring.

 

3.

Mix inlet regulator air tube

3.

Clean with sanitized brush.

 

 

blocked.

 

 

 

4. Product breakdown.

4. Fill freezer with fresh product.

 

 

 

Front door leaks

1. Front door knobs are loose.

1. Tighten knobs.

 

2.

Spigot parts are not lubricated.

2.

Assemble & lube correctly.

 

3.

Chipped or worn spigot "O" rings.

3.

Replace "O" rings.

 

4. "O" rings or spigot installed wrong.

4. Remove spigot and check "O" ring.

 

5.

Inner spigot hole in front door

5.

Replace front door.

 

 

nicked or scratched.

 

 

 

 

 

Hopper will not

1. EPR valve needs adjustment.

1. Adjust EPR valve.

maintain mix

2.

Refrigeration problem.

2.

Check system. Call distributor for service.

temperature below

3.

Hopper cover not fitted properly.

3.

Check hopper cover for proper fit.

45°F (7°C)

 

 

 

 

 

 

 

 

 

18