Product does not | 1. No mix in hopper. | 1. Fill hopper with mix. | ||
dispense. | 2. | Mix inlet regulator tube is plugged. | 2. | Unplug, using small sanitized brush. |
| 3. | Special mix inlet regulator | 3. | Order special mix inlet regulator. |
|
| needed for mix being used. |
|
|
| 4. Drive motor overload tripped. | 4. Automatic reset. Wait 15 to 30 minutes. | ||
| 5. | Drive belt failure. | 6. | Replace drive belt. |
| 6. | 7. | Turn | |
|
|
|
| then restart. |
|
|
| ||
Drive belt slipping or | 1. Worn drive belt. | 1. Call distributor for service. | ||
squealing. | 2. | 2. | Turn | |
|
|
|
| minutes, then restart. |
|
|
| ||
Low overrun. | 1. Mix inlet regulator missing. | 1. Replace mix inlet regulator. | ||
| 2. | Mix inlet regulator "O"ring missing | 2. | Replace mix inlet regulator "O" ring. |
| 3. | Mix inlet regulator air tube | 3. | Clean with sanitized brush. |
|
| blocked. |
|
|
| 4. Product breakdown. | 4. Fill freezer with fresh product. | ||
|
|
| ||
Front door leaks | 1. Front door knobs are loose. | 1. Tighten knobs. | ||
| 2. | Spigot parts are not lubricated. | 2. | Assemble & lube correctly. |
| 3. | Chipped or worn spigot "O" rings. | 3. | Replace "O" rings. |
| 4. "O" rings or spigot installed wrong. | 4. Remove spigot and check "O" ring. | ||
| 5. | Inner spigot hole in front door | 5. | Replace front door. |
|
| nicked or scratched. |
|
|
|
|
| ||
Hopper will not | 1. EPR valve needs adjustment. | 1. Adjust EPR valve. | ||
maintain mix | 2. | Refrigeration problem. | 2. | Check system. Call distributor for service. |
temperature below | 3. | Hopper cover not fitted properly. | 3. | Check hopper cover for proper fit. |
45°F (7°C) |
|
|
|
|
|
|
|
|
|
18