2.Remove the drip tray by gently lifting up to disengage from the support and pulling out. Clean behind the drip tray and front of the freezer with a soap solution.

C.MONTHLY

CAUTION

THE FREEZER HAS AN AIR COOLED CONDENSER AND MUST HAVE PROPERAIR CIRCU- LATION. MAINTAIN 3" OF CLEARANCE AT ALL LOUVERED PANELS. FAILURE TO CLEAN THE CONDENSER FILTER ONAREGULAR BASIS MAY RESULT IN SERIOUS FREEZER DAMAGE AND COULD VOID FREEZER WARRANTY.

1.Remove the condenser filter by lifting up and pulling bottom out and down. Then clean with warm soapy water. Rinse in clean water and shake dry, taking care not to damage the filter in any way.

2.Replace the condenser filter.

D. SEMI-ANNUALLY

1.Check drive belt for proper tension. Push belt in with one finger, belt should deflect about 3/8".

2.Lubricate condenser fan motor with S.A.E. 20 weight oil. Three to six drops is required.

CAUTION

DO NOT OVER LUBRICATE; RESULTING DAMAGE COULD CAUSE MOTOR FAILURE.

3.14EXTENDEDSTORAGE

Refer to the following steps for storage of the freezer over any long period of shutdown time:

A.Turn the OFF-ON switch to the OFF position.

B.Disconnect (unplug) from the electrical supply source.

C.Clean thoroughly with a warm detergent all parts that come in contact with the mix. Rinse in clean water and dry parts. Do not sanitize.

NOTE

Do not let the cleaning solution stand in the hopper or in the freezer barrel during the shutdown period.

D.Remove, disassemble and clean the front door, mix inlet regulator and auger parts. Place the auger flights and the front auger support bushing in a plastic bag with a moist paper towel to prevent them from becom- ing brittle.

16