ERROR CODES

 

Malfunction

Indicator

 

 

 

Program Board

01

ERR

Power Board

02

ERR

Low Torque Error

03

ERR

Clean Error

04

ERR

Barrel Sensor

05

ERR

Hopper Sensor

06

ERR

Drive Motor

07

ERR

 

 

 

To Clear Error Modes

Clean Error 04: Allow freezer to remain on (light blinking) with the power switch in the ON position for ten (10) minutes minimum. Next, place the power switch in the OFFposition for five (5) seconds minimum, then place the power switch in the ON position to restart freezer. All other errors turn power switch off for five (5) seconds minimum. Then place the power switch in the ON position to restart freezer.

O H M S

SENSOR RESISTANCE

60,000

55,000

50,000

45,000

40,000

35,000

30,000

12

16

20

24

28

32

º F

NOTE: SENSOR IS 10,000 OHMS AT 77°

19