2.2 SHIPMENT AND TRANSIT

The freezer has been assembled, operated, and inspected at the factory. Upon arrival at the final destina- tion, the freezer must be checked for any damage which may have occurred during final transit.

With the method of packaging used, the equipment should arrive in excellent condition. THE CARRIER IS RESPON-

SIBLE FOR ALL DAMAGE IN TRANSIT, WHETHER VISIBLE OR CONCEALED. Do not pay the freight bill until the freezer has been checked for damage. Have the carrier note any visible damage on the freight bill. If concealed damage and/or shortage is found later advise the carrier within ten days and request inspection. The customer must place claim for damage and/or shortages in shipment with the carrier. Stoelting, LLC. cannot make any claims against the carrier.

2.3 FREEZER INSTALLATION

WARNING

Installation must be performed by a qualified electri- cian/refrigeration specialist. Incorrect installation may cause personal injury, severe damage to the machine and will void factory warranties.

WARNING

Lifting hazard

Do not attempt to lift freezer manually. Use proper lifting equipment such as a forklift, lift table, or pallet jack, with lifting device positioned beneath the freezer’s base. Ensure that personnel remain clear of suspended load. Failure to do so may result in personal injury and/or damage to the freezer that will void any factory warranties.

Installation of the freezer involves moving the freezer close to its permanent location, removing all crating, setting in place, assembling parts, and cleaning.

A.Uncrate the freezer.

B.Install the four casters. Turn the threaded end into the freezer until zero threads are showing. To level, turn out casters no more than 1/4" maximum, then tighten all jam nuts.

C.The freezer must be placed in a solid level position.

NOTE

Accurate leveling is necessary for correct drainage of freezer barrel and to insure correct overrun.

D.The freezer must have a minimum of 3" (7,5cm)

-6" (15cm) high ambient conditions- of space on all sides and 10" (25cm) at the top for proper circula- tion.

CAUTION

Risk of product damage

Air cooled condenser requires proper ventilation. Failure to provide adequate ventilation will void factory warranties.

E.Water-cooled freezers need an adequate water supply. Install 1/2" (12,7mm) pipe or 1/2" (12,7mm) inside diameter copper water line to the freezer. Connect water outlet to a drain using a 1/2" (12,7mm) inside diameter line. Automatic washer hoses work well for final connections. All water connections must comply with local codes. Fig. 4.

Figure 4. Water/Electrical Connections

CAUTION

Flush all water lines before installation. In stores with sediment in water, add suitable filter or strainer to water inlet.

F.Place the CLEAN-OFF-SERVE switches in the OFF position before continuing. Figure 11.

2.4 INSTALLING PERMANENT WIRING

Permanent wiring is required by local codes, the following procedure must be performed:

WARNING

Hazardous voltage

High voltage will shock, burn or cause death. Turn off and lock out main power disconnect before installing wiring. Do not operate machine with cabinet panels removed.

4