When the switch is placed in the OFF position, the refrigeration system and auger will not operate.
When the switch is placed in the SERVE position, the refrigeration system and auger willoperate auto- matically. The switch should be placed in the SERVE position for normal operation.
C.
The
D.Cab Indicator Light
A flashing light indicates the cab
E.Pump Switch
The pump motor switch is a two position toggle switch. When the switch is placed in the OFF position, the pump will not run. When the switch is placed in the ON position, the pump will run until the preset pressure is reached, then cycle ON and OFF as product is drawn to maintain that pressure.
F.Standby/Serve Switch
The standby/serve switch is a two position toggle switch. When the switch is placed in the standby position the freezer will cycle to maintain a tempera- ture below 41°F
G.Freezing Switch
The freezing switch is a two position toggle switch. When the switch is placed in the MAXIMUM position the freezer will be forced to run 30 seconds after the temperature control is satisfied.
H.High Head Pressure Cut Out
If the head pressure exceeds 445 psig (28 bar) air cooled andwater cooled, the high head pressure cutout will trip. The reset button can be accessed
from the side of the | freezer. |
I.Low Mix Light
The low mix light will illuminate when the liquid level in the mix container drops below two gallons.
J.Front Door Safety Switch
The front door safety switch prevents the auger from turning when the front door is removed. The switch is open when the door is removed and closed when the door is properly installed.
10