3. WALLS NEXT TO A HEARTH

SITE REQUIREMENTS

3. WALLS NEXT TO A HEARTH

Solid, non-combustible material e.g. masonry or concrete

H

150mm

minimum

C

Position of Appliance & Hearth in relation to walls Thickness W

C

150mm

minimum

PR7217R

Position of Appliance & Hearth in relation to walls

Requirement for the walls

 

 

 

 

Distance of hearth from wall

Distance of Appliance to wall

Min thickness of Wall

Min height of wall

'C'

 

'W'

'H'

 

 

 

 

0mm

0mm - 50mm

200mm

Height of appliance + 300mm

 

 

 

Or

 

 

 

 

 

 

1200mm from the hearth (take largest

0mm

51mm - 300mm

75mm

dimension)

 

 

 

 

0 - 150mm

150mm +

75mm

1200mm

 

 

 

 

150mm +

300mm +

No Minimum Requirement

 

 

 

 

Suitable clearance should be allowed around the stove to enable the correct fitting and maintenance of the appliance. Any clearances should be confirmed by making a site survey and a physical check of wall thickness and dimensions.