Stovax 1001 Care of appliance, Seasonal use, Troubleshooting tips, Product Code, Description

Models: 1000 1001 1002

1 26
Download 26 pages 47.42 Kb
Page 10
Image 10
13. Care of appliance

USER INSTRUCTIONS

13. Care of appliance

Stovax has a range of cleaning and maintenance products and accessories to keep your appliance in good working condition. Your Stovax retailer can provide full details but here is a brief list of useful items:

Product Code

Description

 

 

3047

Extra long matches

5039

Gas lighter

4052

Log basket

 

 

3048

Wood sling - for easy carrying of logs

 

 

3016

Log tongs

4027

Extra long protective gloves

5038

Hearthgate - 5 section (for areas 1780x610mm

5044

Hearthgate - 7 section (for areas 1780x405mm)

 

 

4227

Ash caddy - 382x102x306mm

 

 

4228

Ash caddy - 446x102x306mm

4229

Ash caddy - 382x102x459mm

4230

Ash caddy - 637x127x408mm

 

 

4231

Ash caddy - 306x178x459mm

 

 

2091

Ashclean vacuum cleaner attachment

4232

Steel brush

Your retailer can provide genuine spare parts such as replacement glass, door sealing rope and fire bricks when required. An annual service by a competent engineer is recommended to keep your appliance in best possible condition.

14.Seasonal use

14.1Clean and service the appliance if it is not used during the warmer periods of the year as detailed in the Maintenance and Servicing section

14.2Set the air controls 50% open to keep the appliance ventilated and stop the build-up of any moisture inside.

14.3Before re-lighting the appliance:

Remove the baffles

Clear any debris that may have accumulated

Check the flue is clear of any blockages

15.Troubleshooting tips

15.1Appliance is producing tar: This is identified by:

A very strong pungent smell shortly after the appliance is lit and heats up

Thick, brown and sticky tar oozes from the pipe joints

This is caused by burning damp wood and burning your appliance at too low a temperature;

Use well seasoned wood and operate the appliance in the ideal temperature range

Tar is a major cause of chimney fires - if you experience problems with tar build up consult a chimney sweep before continued use of your appliance.

Ideal working temperature range is 130°C and 240°C (270°F – 465°F). Failing to close down the primary air control once the appliance has heated up to this range may cause the appliance to over-fire and to exceed the ideal temperature range. Over-firing can cause permanent damage to the appliance and invalidates your warranty.