2. ADDITIONAL VENTILATION

PRE-INSTALLATION CHECKS

2. ADDITIONAL VENTILATION

2.1Additional ventilation will be required to comply with the requirements of the Building Regulations. This should be provided using a permanently open air vent, of the size listed, which is positioned so that it is not liable to be blocked both inside and outside the building.

2.2Extractor fans or cooker hoods must not be placed in the same room or space as this can cause the appliance to emit fumes into the room.

2.3If any of these checks reveal problems do not proceed with the fitting of the appliance until they have been rectified.

Model

 

Small Regency

Medium Regency

Large Regency

Small Regency - 1000

 

Medium Regency - 1001

 

Large Regency - 1002

 

 

 

 

 

 

 

 

 

mm2

28500

35400

40800

Additional Ventilation

cm2

285

354

408

 

in2

44

55

63

17