Stovax 1002, 1001 EXTENDED burning, Over-Firing, Chimney fire, General Cleaning, Chimney Sweeping

Models: 1000 1001 1002

1 26
Download 26 pages 47.42 Kb
Page 9
Image 9
8.EXTENDED burning

USER INSTRUCTIONS

7.3Remove Ashpan carefully. Heat can remain long after use, See Diagram 12

Use gloves, or place the ash into a Stovax Ash Caddy

(Stovax Part No. 4227)

Remove ash at least once every week when burning wood

Do not place hot ash in a bin made from plastic or any other combustible material.

8.EXTENDED burning

8.1It is possible to lengthen the re-fuelling period. In order to do this:

De-ash prior to final refuelling

Close the doors

Close air controls

Use smokeless fuel or small, thick logs depending on fuel desired

9.OVER-FIRING

9.1Do not over-fill with fuel or use at maximum output for long periods or over-firing can occur. If the flue pipe, flue collar or top plate glow red the appliance is over-firing:

Close the air controls to reduce the output

9.2Over-firing can cause permanent damage to the appliance.

10.Chimney fire

10.1If a chimney fire occurs:

Shut all air controls immediately

Evacuate the building

Call the fire brigade

Do not re-enter the building until it is confirmed safe

10.2Do not use the appliance after a chimney fire until: a) It has been inspected by a registered installer, confirming the appliance is safe to use*

b) The chimney system inspected and swept by a chimney sweep, confirming the system is structurally sound and free from obstruction before re-use.**

c) It is repaired as required before re-use. Use only genuine Stovax replacement parts to keep your appliance in safe and efficient working order.

11.GENERAL CLEANING

11.1Allow appliance to cool thoroughly to avoid risk of burns:

Clean regularly, according to the level of use

Give attention to the baffle system, flue ways and removing ash

Regular cleaning and maintenance will help give many years of safe use.

Clean matt black appliances using Stovax Collodial black or Stovax Grate Polish

To refresh painted finishes use Stovax Thermolac paint.

• Do not use aerosol sprays near an operating appliance

Wipe dry with a soft clean cloth before re-lighting. Do not leave unit without drying, as this may cause rust.

Do not use abrasive cleaner or cleaning pads to clean enamel finishes.

12.CHIMNEY SWEEPING

12.1To maintain safe and efficient use of the appliance the chimney/flue must be inspected and swept at least once a year by a qualified chimney sweep.*

If the appliance is used continuously throughout the year or it is used to burn wood or smokeless fuel, more frequent sweeping is recommended.

The best time to have the chimney swept is at the start of the heating season.

The above applies even if burning smokeless fuels.

12.2The chimney, any connecting flue pipe and the appliance flue ways if incorporated, must be regularly cleaned.

12.3Ensure adequate access to cleaning doors where it is not possible to sweep through the chimney.

12.4If the chimney is believe to have previously served an open fire the chimney must be swept a second time within a month of regular use after installation.

In the U.K:

*registered with HETAS (GB only)/INFO (Republic of

Ireland only)

**This should be done by a NACS registered (UK only)/

INFO registered (Eire only) chimney sweep, who will issue you with a certificate.

9

Page 9
Image 9
Stovax 1002, 1001, 1000 EXTENDED burning, Over-Firing, Chimney fire, General Cleaning, Chimney Sweeping, User Instructions