Stovax 5 Installation Instructions, Technical Specification, Covering the following models, Model

Models: 5

1 23
Download 23 pages 30.25 Kb
Page 8
Image 8
INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

TECHNICAL SPECIFICATION

Covering the following models

8575 MCUC P8575 MCUC

Model

Gas

Gas

Working

 

NOX

Aeration
Injector
Gas Rate
Input kW (Gross)
Country

CAT.

 

Type
Pressure

 

Class

 

 

m3/h

 

 

 

 

 

 

 

High

Low

 

 

 

 

 

 

 

 

 

 

 

 

 

Stockton 5

I2H

Natural Gas

20 mbar

 

5

1 x 7.5mm

260

0.435

4.6

2.5

GB, IE

8575

 

G20

 

 

 

 

 

 

Gross

Gross

 

 

 

 

 

 

 

 

 

 

 

 

 

Stockton 5

I3P

LPG Propane

37 mbar

 

5

1 x 13.5mm

110

0.170

4.4

2.3

GB, IE

P8575

 

G31

 

 

 

 

 

 

Gross

Gross

 

 

 

 

 

 

Efficiency Class II

 

 

 

 

 

 

 

 

 

Flue Outlet Size 127mm (5”) ø

 

 

 

 

 

 

 

 

Gas Inlet Connection Size 8mm ø

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum flue specification

T260 / N2 / O / D / 1

 

 

 

 

 

 

Maximum flue temperature

180°C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Packing Checklist

Qty Description

1 Stove

1Flue infill plate

1Front coal

1Flame baffle

1Coal set

1Rear ceramic

1Fixing kit containing:-

1Instruction manual

2Wood screws

2Rawlplugs

1Allen key

AR1451