Stovax 8455 User Instructions, Oxygen Depletion Sensor, The Flame Failure Device, 10.’RUNNING IN’

Models: 8455

1 26
Download 26 pages 56.52 Kb
Page 8
Image 8
AR1128

USER INSTRUCTIONS

16

AR1128

7.17Place the remaining 6 small coals on top of the others so that they form a bridge between the second and third rows. See Diagram 17.

17

AR1129

8. OXYGEN DEPLETION SENSOR

The appliance is fitted with an oxygen sensitive pilot system which will act to cut off the gas supply to the fire should the oxygen in the room fall below its normal level. If the fire is turned off by this device, it usually indicates that there is a problem with the flue system, and this should be inspected by a qualified engineer.

Do not attempt to use the fire until an engineer says it is safe to do so.

This device is not a substitute for an independently mounted carbon monoxide detector.

9. THE FLAME FAILURE DEVICE

This is a safety feature incorporated in all GAZCO fires which automatically switches off the gas supply if the pilot light goes out and fails to heat the thermocouple.

10.’RUNNING IN’

The surface coating on the coals used in your GAZCO fire will ‘burn off’ during the first few hours of use, producing a harmless and temporary odour. This will disappear after a short period of use. If the odour persists, ask your installer for advice.

11. SERVICING

This fire must be serviced every 12 months by a qualified Gas Engineer. In all correspondence, always quote the appliance type and serial number, which may be found on the databadge, adjacent to the control knob.

12. VENTILATION

Any purpose provided ventilation should be checked periodically to ensure that it is free from obstruction.

13. INSTALLATION DETAILS

To assist in any future correspondence, your retailer should have completed this commissioning sheet, this records, the essential installation details of the appliance. In all correspondence always quote the model No and serial No.

8

Page 8
Image 8
Stovax 8455 User Instructions, Oxygen Depletion Sensor, The Flame Failure Device, 10.’RUNNING IN’, Servicing, Ventilation