COMMISSIONING

4.2Close the door by pushing the lower right corner of the door until a click is heard. The door will now have latched. Opening is done by the lower right hand door, again until a click is heard, and opening to its stop.

5. COMMISSIONING

NOTE: THE HANDSET HAS BEEN FACTORY PROGRAMMED TO OPERATE THIS APPLIANCE. IF THE HANDSET OR CONTROL UNIT HAS BEEN REPLACED, IT WILL BE NECESSARY TO FOLLOW THE PROGRAMMING PROCEDURE.

PROGRAMMING THE HANDSET

Section 5 must be read in total before trying to programme the handset! The sequence must be performed while the ON/OFF on the display is still flashing.

5.1Open the lower door by pressing until a ‘click’ is heard. Now switch the button on the control unit to the Unlock position COMMISSIONING . See diagram 18.

18

AR1676

5.2The remote handset must now be programmed. Push the ON / OFF button (11), the ON or OFF display will start flashing. Then

press the ON / OFF button (11), and the ( 5. COMMISSIONING ) (10) and ( Manual background ) (13) buttons at the same time.

Immediately after press the SET button (12) once. See diagram 19.

19

 

 

6

 

 

 

 

 

 

 

1:

Flame display

 

 

 

 

 

 

 

7

 

 

 

 

 

4 5

2:

Celsius display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3:

Temperature display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

 

 

 

 

 

 

 

 

 

 

1

4:

On display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5:

Off display

 

 

 

 

 

2

9

 

 

 

 

 

6:

Low battery display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 3

7:

Clock display

12

 

 

 

 

 

 

 

8:

Auto display

 

 

 

 

 

 

 

 

 

 

 

 

11

9:

Manual display

 

 

 

 

13

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10: UP button

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11: ON/OFF button

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12: SET button

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13: DOWN button

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AR1665

5.3The clock (7) will appear on the display. After a few seconds this will disappear.

5.4Finally push the switch to the Lock position Manual background , towards the rear of the appliance. The remote should now be tuned to the control box.

5.5Close the lower door untill a ‘click’ is heard.

5.6Close all openable doors and windows in the room, ignite the appliance and operate on maximum for 10 minutes. Remove the plastic sight plug from the right hand side of the appliance. Position a lighted smoke match just inside the draught diverter opening and check that all smoke is drawn into the opening by viewing through the sight hole. See diagram 20. If there is any doubt, run the appliance for a further 10 minutes, and repeat the test.

20

AR1493

5.7If there are any extractor fans in adjacent rooms, the test must be repeated with the fans running on maximum and interconnecting doors open.

IF SPILLAGE PERSISTS, DISCONNECT THE APPLIANCE AND SEEK EXPERT ADVICE.