10.GAZCO FLUE SURE SYSTEM

SERVICING INSTRUCTIONS

REPLACING PARTS

10.GAZCO FLUE SURE SYSTEM

10.1Open and remove the front door. Remove the glass frame. Carefully remove the ceramic components and place to one side. Undo the two screws at the back of the firebox and carefully withdraw the bracket. See diagram 16

16

AR1442

10.2Disconnect the two sender wires. Undo the two taptite screws and remove the sensor and the two plastic spacers. See diagram 17

17

AR1446

10.3Refit the new sensor ensuring that the plastic spacers are between the sensor and the bracket. Refit the leads. See diagram 18

18

AR1452

10.4Feed the cable back through the hole as you replace the bracket. When the bracket is located correctly it will sit flush with the back panel without force required. If not positioned correctly the bracket will sit at an angle. See diagram 19

19

AR1447

AR1448

11. CHANGING BETWEEN GAS TYPES

In order to change between gas types, it will be necessary to change the following items

Pilot Unit

Control Valve**

Main Injector

Aeration Plate

Control Unit

Data Badge

The relevant parts can be ordered from Gazco, always quote the appliance type and serial number when ordering spare parts.

**NOTE: THE CONTROL VALVE IS FACTORY PRESET FOR CORRECT GAS TYPE AND MODEL, A NEW UNIT WILL NEED TO BE ORDERED WHEN CHANGING BETWEEN GAS TYPES.