Studer Innotec HPC 2800-12, HPC 4400-24, HPC 6000-48, HPC 8000-48 Push buttons, Turning Knobs

Models: HPC 2800-12, HPC 4400-24, HPC 6000-48, HPC 8000-48

1 26
Download 26 pages 16.28 Kb
Page 14
Image 14

 

STUDER INNOTEC

HP-COMPACT

 

 

 

 

 

 

 

 

 

 

Display the value of the output power in % of Pnom (in

 

25

 

POWER

Inverter Mode) and the charge current in Amps (in Charger

 

 

MONITOR

Mode). In this mode the red LED indicates that power

 

 

 

 

 

 

 

sharing is in use (>100A).

 

4.3

Push buttons

 

 

 

 

 

 

 

 

19

 

ON/OFF

Turning the HP-COMPACT on and off (Help Button for

 

 

Programming)

 

 

 

 

 

20

 

RESET

Alarm Signal off (Help Button for Programming)

 

21

 

Aux. Contact

Control Aux. contact (Help Button for Programming)

 

4.4

Turning Knobs

 

 

 

 

 

 

 

 

22

 

CHARGER

Adjustment for max. Charging Current

 

23

 

TRANSFER

Adjustment for Transfer Voltage Threshold (TRANSFER –

 

 

INVERTER)

 

 

 

 

 

24

 

STANDBY

Adjustment for „Standby“ system

 

26

 

INPUT LIMIT

Must be adjusted to the maximal available current of your

 

 

AC INPUT supply

 

4.5

The Inverter

 

 

An Inverter is built in the HP-COMPACT, which generates a sinusoidal alternating voltage of a very high quality. With this Inverter any 230Vac alternating voltage appliance up to the nominal power of your HP-COMPACT can be operated. Thanks to the generous dimensioning of the HP-COMPACT, you can operate appliances requiring higher power than the nominal power of the HP-COMPACT for a short time. The HP-COMPACT provides up to 3-times the nominal power to start motors.

The Inverter mode is displayed through LED 9 (Inverter). If the Inverter Mode is disabled (see chap. 5.5) LED 9 will blink. If the LED 9 is lit, the Inverter is in operation and you have 230Vac at the output AC OUT. The actual power of the connected appliance is displayed on the power monitor 25 and on the Remote Control.

4.5.1 Charge detection system „Standby“

In order to avoid unnecessary discharge of the battery, the inverter switches OFF automatically if no appliance is connected and switches ON automatically again if appliance is connected. The LED 8 blinks if the inverter is in Standby-Mode. The switching-on/starting level can be adjusted with the turning knob 24 „STANDBY”. Adjusting the switching-on level is as follows: Switch off all consuming devices, turn the Turning Knob 24 to the right until the LED 8 is blinking, switch on the smallest consuming device (i.e. Mobile phone charger), turn the Turning Knob slowly to the left until LED 8 is lit.

If the Standby-Mode is not wanted, turn the Turning Knob 24 to the left, to the OFF position.

4.5.2Overload

If the Inverter is too long or too heavily overloaded, it switches off. The LED 11 „Overload“ is lit and LED 13 „OFF“ blinks. After ca. 10 seconds the Inverter switches on automatically. If the Inverter is overloaded four times one after another in a short

HP-COMPACT V5.4