S U B - Z E RO MODEL 315W I N S TA L L AT I O N

ELECTRICAL R E Q U I R E M E N T S

KICKPLATE A I R F L O W

A 115 V AC, 60 Hz, 15 amp circuit breaker and electrical supply are required. A separate circuit is required for each unit.

The Model 315W is equipped with a power supply cord with a 3-prong grounding plug, which must be plugged into a mating 3-prong grounding-type wall receptacle. Refer to the illustration below. Follow the National Electrical Code and local codes and ordinances when installing the receptacle. For location of the electrical supply, refer to the Rough Opening Dimensions illustration on page 6.

IMPORTANT NOTE: A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation.

Do not use an extension cord or two- prong adapter. Electrical ground is required on this appliance. Do not remove the power supply cord ground prong.

The wine cooler uses a fan to take in room air through vents in the left side of the kickplate, and discharges warm air through vents in the right side. These vents must be kept clear of obstructions or decorative panels. Blocking or obstructing the kickplate will restrict air flow and cause a decrease in performance and efficiency. Refer to the illustration below.

IMPORTANT NOTE: The minimum air temperature the wine cooler will operate in is 50˚F (10˚C), and the maximum is 100˚F (38˚C).

MOVING T H E U N I T

IMPORTANT NOTE: When you move the unit using a hand truck or dolly, position the dolly on the side of the unit and secure the door so it does not open while transporting.

IMPORTANT NOTE: When moving and installing the Model 315W/S, be sure to protect all stainless steel surfaces from scratches.

Once the unit is in place, remove any tape or other packaging material from the inside. Check that all wine shelves fully extend.

Any finished flooring should be protected with appropriate material to avoid any damage from moving the unit.

LINE POWER (VOLTAGE)

NEUTRAL

GROUND

Grounded electrical outlet

C

OL

 

 

D

 

E

 

R

ROOM AIR IN

 

WARM AIR OUT

Kickplate airflow

7

Page 7
Image 7
Sub-Zero manual B Z E RO Model 315W I N S TA L L AT I O N, Electrical R E Q U I R E M E N T S Kickplate a I R F L O W