INSTALLATION INSTRUCTIONS
INSTALLATION
IAWARNING I
Step 9
Unit is equipped with rollers. Plug into 15 amp grounded outlet and roll unit into desired position under the wood block or soffit and connect icemaker water line to unit. Remove garden hose fitting from plastic bag and attach the '/4" compression nut and sleeve on copper tubing before attaching the hose fitting to the solenoid valve. Purge line before final hookup to valve. See Figure
13.For Model 590 see
Figure 14.
Turn on water supply and check all fittings for leaks. Make certain electrical harness Is attached to solenoid.
NOTE: Icemaker will not immediately fill with water when supplied to valve. Allow 24 hours for proper ice production.
MODELS 511, 532, 542, 550, 561 AND501F
SOLENOID VALVE
Figure 13
MOOEL590
Figure 14
Step 10
Level the unit. To adjust height, turn front leveling legs counterclockwise to raise, or clockwise to lower. Rear levellers (rollers) are adjusted from front of base. Turn 5h6" hex bolt clockwise to raise cabinet, counterclockwise to lower cabinet. See Figure 12.
Step 11
Install toe plate as shown in Figure 15.
Before attaching toe plate check to ensure drain pan is installed properly.
IACAunON I
Toe plate must be removable for servicing, so any flooring must allow for this removal. Refer to label mounted on kickplate support for height clearance.
Step 12
Install grille, step 7.
IMPORTANT: For Models 511, 532, 542, 550, 561 and 590, reverse step 7 procedure. NOTE: If using panelized grille refer to "Grille Panel Installation. "
Step 13
Restore power to the wall outlet.
PANEL
INSTALLATION
Step 14
Apply decorative front panels (and side panels if applicable).
All
FRONT PANEL
INSTALLATION
(See
If a metal or other thin material is used, a filler must be in- serted behind your panel to insure a proper fit. All frames are designed to accept up to '/4" material. If a raised, wood front panel is being used, the edges must be routed to the necessary '/4" border specifi- cations. (50# per door panel maximum weight limit)
NOTE: ROUTING, RECESSING OR OP· TlONAL EXTENDED HANDLES MAY BE REQUIRED ON RAISED PANELS FOR FINGER CLEARANCE UNDER HANDLE. Refer to Figures 28 and 29 - "Handle Recess Specifications and Recommendation for Raised Panels."
NOTE: does not apply to Model 590.
MODELS 501F, 501R, 511, 532, 542, 550 AND 561
A)To install front panels on your
NOTE: the molding will bend at center allowing removal as in Figure 16.
Figure 15
5