Electrical

BUILT-IN REFRIGERATION

Electrical

The electrical supply should be located within the shaded area shown in the illustration below. A separate circuit, ser- vicing only this appliance is required. A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation.

Installation must comply with all applicable electrical codes.

ELECTRICAL REQUIREMENTS

 

Electrical Supply

115 VAC, 60 Hz

Service

15 amp

Receptacle

3-prong grounding-type

7"

E

(178)

 

 

6"

(152)

751/2" (1918)

 

FROM FLOOR

 

RIGHT SIDE

 

OF OPENING

 

Electrical supply location.

Plumbing

The water supply line should be located within the shaded area shown in the illustration below. The water supply line should be connected to the house supply with an easily accessible shut-off valve. Do not use self‑piercing valves. The water supply line must not interfere with installation of the anti-tip brackets.

A reverse osmosis system can be used provided there is constant water pressure of 35–120 psi (2.4–8.3 bar) supplied to the unit at all times. A copper line is not recommended for this application.

Installation must comply with all applicable plumbing codes.

PLUMBING REQUIREMENTS

Water Supply1/4" OD copper, braided stainless steel or PEX tubing

Pressure

35–120 psi (2.4–8.3 bar)

Excess Line for Connection

36" (914)

RIGHT SIDE

OF OPENING

18" (457)

6" (152)

 

3" (76)

AREA EXTENDS 1/2" (13)

FORWARD ON FLOOR

 

Water supply location.