Sub-Zero PRO 48 installation instructions E C T R I C a L R E Q U I R E M E N T S

Models: PRO 48

1 76
Download 76 pages 10.47 Kb
Page 10
Image 10

P R O 4 8 I N S T A L L A T I O N I N S T R U C T I O N S

E L E C T R I C A L R E Q U I R E M E N T S

A220-240 V AC, 50/60 Hz, 10 amp circuit breaker and electrical supply are required. A separate circuit, servicing only this appliance, is required. Locate the electrical outlet within the shaded area indicated in the Installation Specifications illustration on the previous page.

The PRO 48 is equipped with a detachable power supply cord with a 3-prong grounding plug, which must be plugged into a mating

3-prong grounding-type wall receptacle. Follow local codes and ordinances when installing the receptacle.

IMPORTANT NOTE: A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation.

IMPORTANT NOTE: The PRO 48 is equipped with an appliance inlet type device. This allows easy replacement of the power cord. The appli- ance inlet is located on top of the unit on the compressor shroud.

Do not use an extension cord or two prong adapter. Electrical ground is required on this appliance. Do not remove the power supply cord ground prong.

The outlet must be checked by a qualified electrician to be sure that it is wired with the correct polarity. Verify that the outlet provides 115 volts and is properly grounded.

Always shut power off at the circuit breaker before performing any installa- tion, service or maintenance.

10