Sub-Zero PRO 48 installation instructions S TA L L AT I O N Specification S

Models: PRO 48

1 76
Download 76 pages 10.47 Kb
Page 8
Image 8

P R O 4 8 I N S T A L L A T I O N S P E C I F I C A T I O N S

I N S TA L L AT I O N S P E C I F I C A T I O N S

The PRO 48 can be used free-standing or installed as a standard or flush built-in application. For standard built-in installa- tions, the face frame of the unit will extend

51mm beyond cabinetry. In flush built-in installations, the front of the face frame will be flush with surrounding cabinetry.

For built-in installations, make sure that the finished rough opening where the unit is to be installed is properly prepared. Refer to the Installation Specifications illustration to be sure that the rough opening dimensions, electrical service and plumbing are correct.

IMPORTANT NOTE: To operate properly, doors must be able to open a minimum of 90˚. Use a filler strip in built-in corner installations to assure a 90˚ door opening. Allow enough clearance in front of the unit for full door swing.

IMPORTANT NOTE: Make sure that the floor under the unit is level with the surrounding finished floor and will be able to support the weight of the unit—401 kg or 408 kg.

8

Page 8
Image 8
Sub-Zero PRO 48 installation instructions S TA L L AT I O N Specification S