Summit HP-1L, HP-1S user manual Diagnosis Solution

Models: HP-1S HP-1 HP-1L

1 25
Download 25 pages 38.82 Kb
Page 15
Image 15

OPERATION

B. Controller Display:

The controller display is a multifunction visual display. It can provide three types of information: i) ON/OFF status, ii) battery condition meter and iii) fault diagnostics.

1. ON/OFF Status

When the power is on, the controller's LED will be lit up. If the LED is not lit, the controller is OFF.

2.Battery Condition Meter

The battery condition meter is composed of 6 segments (two each of red, orange, and green). It enables you to monitor battery charge. The battery condition meter indicates the approximate amount of battery charge left.

B Red, orange and green LEDs indicate that the batteries are fully charged.

B Red and orange LEDs indicate that you should charge the batteries if possible.

BRed LEDs indicate that you should charge the batteries as soon as possible, because low battery voltage may cause your power wheelchair to become inoperative.

Note: When the batteries begin to approach a discharged state, the first red LED will begin to flash slowly, reminding you that the batteries need to be charged immediately.

3. Diagnostics:

The controller's LEDs can also indicate some common causes of problems with your power wheelchair. The following chart lists possible problems indicated by the flashing meter:

 

FLASH CODE SEQUENCE

DIAGNOSIS

SOLUTION

 

 

 

 

1.

•___•___•___

Low battery voltage fault

Check Batteries/Battery Wiring

2.

••___••___••___

High battery voltage fault

Check Batteries

3.

•••___•••___

Left motor (or connection)

Check Left Motor Wiring

 

 

Fault

 

4.

••••___••••___

Right motor (or connection)

Check Right Motor Wiring

 

 

fault

 

5. ••••• ___•••••___

Left or right park brake (or

Check Motor/Brake Wiring

 

 

connection) fault

 

6.

••••••___••••••___

Controller fault

Contact your Authorized Dealer

7.

•••••••___•••••••___

Motor stalled or joystick

Reset the Power On/Off Button

 

 

out of neutral time out

 

 

 

 

 

Where

” means all 6 LED’s flash on for a period of 0.2 seconds and off for 0.8 seconds

“___” means all 6 LED’s are off for a period of two seconds before flashing sequence

repeats

Page 13

Page 15
Image 15
Summit HP-1L, HP-1S user manual Diagnosis Solution