Sun Microsystems 240 manual Environmental and Safety Specifications

Models: 240

1 26
Download 26 pages 50.93 Kb
Page 18
Image 18

P14 Netra 240 Server Architecture

Sun Microsystems, Inc.

The following table summarizes the Netra 240 server’s enclosure and power specifications.

Table 2-2: Enclosure and power specifications of the Netra 240 server.

Configuration

Netra 240 Server

Dimensions

Height: 87.4 mm (3.44 in.) – 2 RU

 

Width: 425 mm

(16.73 in.) without bezel

 

442 mm

(17.4 in.) including bezel

 

Depth: 483 mm (19 in.) to rear connectors

 

508 mm

(20.0 in.) overall max.

Weight

16.3 kg (36 lbs.)

 

 

18.6 kg (41 lbs.) fully configured with rackmount kit

Power

90–264 V AC (47-63 Hz) / -48 V DC or -60 V DC nom (-40 to -75 V DC range)

 

6.1 amps maximum (at 90 V AC) and 15 amps maximum (DC)

 

Dual, redundant 400 Watt power supplies

Environmental and Safety Specifications

As summarized in the following table, the Netra 240 server meets all relevant domestic and international agency safety, ergonomics, EMI, and environmental requirements.

Table 2-3: Environmental and safety specifications of the Netra 240 server.

Specification

Operating

Nonoperating

Ambient temperature

AC: 0° C (32° F) to 40° C (104° F)

AC: -40° C (-40° F) to 70° C (158° F)

 

DC: -5° C (23° F) to 45° C (113° F)

DC: -40° C (-40° F) to 70° C (158° F)

 

 

 

Relative humidity

AC: 10% to 90% (noncondensing),

AC: Up to 93% (noncondensing)

 

40° C max wet bulb

 

 

DC: 5% to 93% (noncondensing)

DC: Up to 93% (noncondensing)

Altitude

Up to 3000 m

Up to 12,000 m

Acoustic noise

Operating: 7.0 B

(ISO 9296)

Idling: 7.0 B

 

 

 

ETSI

EN 300 019-2-1,2,3, Table 3.1 & 3.1 E

 

 

Seismic

GR-63-Core requirements for earthquake Zone 4

 

 

Safety

IEC60950, UL/CSA60950, EN60950

 

 

RFI/EMI compatibility

FCC Class A, Part 14 47 CFR, EN55022, CISPR 22, EN 300-386:2001 V1.3.1, ICES-003

 

 

 

Immunity

 

EN55024

 

 

 

Certifications

 

 

Safety

cULus Mark, TUV GS Mark, CE Mark, CCC, GOST R

EMC

CE Mark (93/68/EEC), FCC authorized Class A, VCCI, BSMI, C-Tick, MIC

Telecommunication

Telcordia GR-63 CORE, GR-1089-CORE, SR 3580 NEBS Level 3

 

 

 